background image

INSTALL PUMP (AIRGO ALL TERRAIN)

WWW.BIGASSFANS.COM     © 2018 DELTA T LLC     ALL RIGHTS RESERVED.

CAUTION:

 Do not operate misting pump without filter.

CAUTION:

 Do not plug fan into outlet on misting pump.

OPERATION

Water supply requirements:
15–60 PSI, 140°F (60°C) max

1.  Turn off fan.
2.  Plug in misting pump (20 A circuit).
3.  Turn on water source.
4.  Press red button on pump filter to purge air.
5.  Flip Power switch to ON.
6.  Press Start switch.
7.  Turn on fan.

To stop misting, 

flip Power switch to OFF and turn off 

water source.

Power 

Switch

4. CONNECT HOSE

5. CONNECT WATER SOURCE

5/16-18 Nylock Nut

Start 

Switch

Operating Instructions and Maintenance:

bigassfans.com/support

AIG-INST-214-ENG-01   REV A   09/06/18