Installation, Operation and Maintenance Manual
VCIOM-01249-EN Rev. 0
Installation
19
Section 3: Installation
Figure 18
1
2
Table 8.
Actuator size
Oil quantity (l)
F01-2000/150
0.7
F01-2000/300
0.7
F01-2000/600
0.8
3.10
Installation in Environment with
Explosive Dusts
NOTICE
Electric actuator F01-2000 shall be installed and maintained according to the applicable
rules regarding the electrical installations in hazardous area (other than mines) classified as
zone 21 (dust); example: EN 61241-14 (dust) and/or other national standards.
Please make sure that:
•
The joint surfaces are greased with silicon oil or equivalent before assembly.
•
The cable glands have minimum protection degree IP68 (EN 60529).
•
Periodically verify the quantity of dust deposited on the enclosure and clean it if
more than 5 mm.