Installation, Operation and Maintenance Manual
VCIOM-15345-EN Rev. 1
February 2022
23
Start-up Procedure
Section 4: Start-up Procedure
Section 4: Set-up/Start-up Procedure
In addition to this set-up/start-up procedure, the following documentation will be
necessary to fulfill all set-up and start-up requirements.
1.
General Arrangement drawing
2.
Bill of Material
3.
Schematic drawing
4.
Wiring Diagram drawing
When using these instructions, refer to the schematic diagram, wiring diagram, general
arrangement drawings for the Biffi EHO and the certified bills of material.
Numbers in [ ] correspond to components labeled on the wiring diagram. Numbers in ( )
correspond to components labeled on the schematic diagram. Information in (( ))
is descriptive.
When the Biffi EHO is delivered to the job site, it has been both pressure and function
tested. The oil reservoir was filled to operation level when it shipped from factory.
4.1
Preparation
4.1.1
Safety First
Hydraulic Pressure
!
WARNING
Ensure that test personnel and witnesses are properly informed of the hazards involved with
high pressures and the proper safety barriers are employed. Never check for leakage using
your fingers or hands. Fluid under high pressure can inject into the skin and cause severe
damage or death. Always use an implement such as a piece of paper.
Safety Equipment
!
WARNING
All personnel in the testing area must always wear safety glasses.
4.1.2
Material and Equipment for Start-up and Set-up
To complete this procedure, you will also need the following materials and equipment:
Table 5.
Required Material and Equipment
Required Material and Equipment
Miscellaneous fittings, adapters and Hand Tools: complete complement of open end
((SAE and metric)) wrenches, screw drivers Philips and flat blade and a set of hex wrenches
Primary Power Source for the Biffi EHO
((check the Biffi EHO System Electrical Diagram for requirements))
Supplemental quantity of hydraulic fluid, if needed
((See Section 2.7, Hydraulic Fluid, and Biffi EHO specification for required fluid type))
Nitrogen Source ((if an Accumulator is supplied with the Biffi EHO))