March 2021
Installation, Operation and Maintenance Manual
MAN 604-1A Rev. 6
Operation and Use
18
Section 3: Operation and Use
3.1.3
Travel Stop-screw Screwed on the End Flange of
Spring Container
For the adjustment of the travel stop-screw, proceed as follows:
For the adjustment of the travel stop screw, proceed as follows:
1.
Loosen the lock nut “d”.
2.
If the actuator angular stroke is stopped before reaching the end position,
unscrew the stop screw “v” by turning it anticlockwise until the valve reaches the
correct position.
3.
If the stop-screw is too hard to be operated, reduce or remove the cylinder
pressure, in order to move the mechanism far from the screw. Operate the
setting-screw and then pressurize again the cylinder to reach end position.
4.
If the actuator angular stroke is stopped beyond the end position, screw the stop
screw by turning it clockwise until the valve reaches the correct position.
5.
Tighten the lock nut, after having correctly placed the threaded seal washer “s”
and “w”.
Figure 16
For model from 006 to 150
Figure 17
For model from 200 to 19600