55
Installation, Operation and Maintenance Manual
MAN 564 Rev. 6
June 2020
Troubleshooting
Section 6: Troubleshooting
Section 6: Troubleshooting
6.1
Failure or Breakdown Research
Table 24.
Event
Possible cause
Remedy
Actuator does not work
Lack of power supply
Restore it
Lack of pneumatic supply
Open line interception valve
Blocked valve
Repair or replace
Wrong position of the distributor of
the manual hydraulic group
Restore correct position
Failure of the control group
Call Biffi Italia s.r.l.
Customer Service
Low supply pressure
Restore (Section 1.4)
Actuator too slow
Low supply pressure
Restore (Section 1.4)
Wrong calibration of flow regulator valves Restore (Section 3.6)
Wear of the valve
Replace
Actuator too fast
High supply pressure
Restore (Section 1.4)
Wrong calibration of flow regulator valves Restore (Section 3.6)
Leakages on hydraulic
or pneumatic circuits
Deterioration and/or damage to gaskets
Call Biffi Italia s.r.l.
Customer Service
Incorrect position of
the valve
Wrong adjustment of mechanical stops
Restore (Section 3.4)
Wrong warning of micro-switches
Restore (Section 3.5)
Hydraulic manual
pump does not work
Handle positioned on remote control
Position the handle on the
indication of the operation
to make
Leakages on the check valve of
the hydraulic control group
Call Biffi Italia s.r.l.
Customer Service