AC Switch/Receiver initialization
Reset AC switch (reset all address)
Press button, keep > 7 sec and wait until red LED blinking.
After red LED blinking let go button and short press button.
Should be Relay switching.
Set AC Switch/Receiver 1 to address 1
Reset AC switch 1
2345A0
and wait answer SMS - if set auto mode, disable auto mode
2345R0
and wait answer SMS - reset all outputs
2345S1
and wait answer SMS - set outputs 1
press button on AC Switch/Receiver 1
Power OFF-ON on BR900-SMT-RF device
wait AC Switch/Receiver 1 Relay switching
Power OFF-ON on BR900-SMT-RF device
if AC Switch/Receiver 1 turned ON, then address installation OK
2345R0
and wait answer SMS - reset all outputs
Set AC Switch/Receiver 2 to address 2
Reset AC switch 2
2345A0
and wait answer SMS - if set auto mode, disable auto mode
2345R0
and wait answer SMS - reset all outputs
2345S2
and wait answer SMS - set outputs 2
press button on AC Switch/Receiver 2
Power OFF-ON on BR900-SMT-RF device
wait AC Switch/Receiver 2 Relay switching
Power OFF-ON on BR900-SMT-RF device
if AC Switch/Receiver 2 turned ON, then address installation OK
2345R0
and wait answer SMS - reset all outputs
Set AC Switch/Receiver 3 to address 3
Reset AC switch 3
2345A0
and wait answer SMS - if set auto mode, disable auto mode
2345R0
and wait answer SMS - reset all outputs
2345S3
and wait answer SMS - set outputs 3
press button on AC Switch/Receiver 3
Power OFF-ON on BR900-SMT-RF device
wait AC Switch/Receiver 3 Relay switching
Power OFF-ON on BR900-SMT-RF device
if AC Switch/Receiver 3 turned ON, then address installation OK
2345R0
and wait answer SMS - reset all outputs