8 General

information

8.1 Terms of guarantee

Bien-Air Dental SA grants the user a
warranty covering any operating fault,
or material or manufacturing defect.

The warranty period for this medical
device is 12 months from the date of in-
voicing.

In the event of a justified claim, Bien-Air
Dental SA or

its authorised

rep-

resentative will repair or replace the
product free of charge.

All other claims of any kind whatsoever,
particularly claims for damages, are ex-
cluded.

Bien-Air Dental SA cannot be held li-
able for damage or injury and the
consequences thereof, resulting from:

l

Excessive wear and tear

l

Infrequent or improper use

l

Failure to observe the servicing,
assembly or maintenance in-
structions

l

Damage caused by unusual chem-
ical, electrical or electrolytic
influences

l

Faulty air, water or electrical con-
nections.

CAUTION

The warranty becomes null and void if
damage and its consequences result
from incorrect servicing or modification
by third parties not authorised
by Bien-Air Dental SA.
Warranty requests will only be taken
into consideration if the product is ac-
companied by a copy of the invoice or
delivery note. The following information
must be clearly indicated: purchase
date, product reference and serial num-
ber.

8.2 References

8.2.1 Set supplied (see cover)

REF

Legend

1601055-001

CA 1:2.5 L MS contra-angle

8.2.2 Optional accessories

(see cover)

REF

Legend

1600617-006

Aquacare,

cleaning

spray

for

physiological liquid 500m, box of
6 cans

1600036-006

Spraynet, 500ml cleaning spray,
box of 6

1600064-006

Lubrifluid, 500ml spray lub-
ricant oil, box of 6

1600001-010

Cleaning wire, box of 10

17

Summary of Contents for CA 1: 2.5 L MS

Page 1: ...Rx Only CA 1 2 5 L MS ENG INSTRUCTIONS FOR USE Other languages available on www bienair com ifu REF 2100337 0002 2020 06...

Page 2: ...REF 2100337 0002 2020 06 CA 1 2 5 L MS Bien Air Dental SA Set supplied REF CA 1 2 5 L MS 1601055 001 Optional accessories REF 1600617 006 1600036 006 1600064 006 1000001 010...

Page 3: ...r maintenance 10 6 1 2 Suitable maintenance products 10 6 2 Cleaning 11 6 3 Disinfection 13 6 3 1 Manual cleaning disinfection 13 6 3 2 Automatic disinfection 13 6 4 Lubrication 15 6 4 1 Verifying cle...

Page 4: ...ht or moderate injury or damage to the device if the safety instructions are not cor rectly followed Recyclable materials Use rubber gloves After initial mechanical resistance tighten fully in the dir...

Page 5: ...elating to medical devices Those medical devices comply with the legislation in force 2 3 Intended use Product intended for professional use only Used in general dentistry and oral surgery WARNING Any...

Page 6: ...n medical devices that are contaminated or potentially con taminated must comply with universal precautions in particular the wearing of personal protective equipment gloves goggles etc Pointed and sh...

Page 7: ...Technical data Contra angle 1 2 5 Standard coupling As per ISO standard 3964 Drive speed 40 000 rpm max Speed of rotation 100 000 rpm max Typical operating torque 1 5 Ncm Transmission ratio Red instru...

Page 8: ...m surgical burs the user must ensure by selecting the correct operating conditions that there is no danger to the user patient or third parties WARNING Follow the guidelines for use according to the b...

Page 9: ...ust not be started without a bur inserted Comply with maximum lengths by always inserting the bur as far as possible into the locking mech anism If a bur is operated at high speeds when incorrectly mo...

Page 10: ...ts Using other products or parts may cause faults during operation and or void the warranty CAUTION l Carry out cleaning disinfection sterilisation without a bur in the chuck mechanism l Do not immers...

Page 11: ...tap water at 15 C 38 C 2 Carefully remove all traces of dirt or deposits from the nozzles using the Bien Air cleaning wire optional 3 After selecting the appropriate end piece perform preliminary cle...

Page 12: ...al and external cleaning 1 After selecting the appropriate end piece spray the inside and the out side of the device with the product Spraynet FIG 6 and FIG 7 2 Dry with non woven compresses 12 FIG 6...

Page 13: ...rfaces with sterile non woven compresses im pregnated with sterile demineralized water 4 Eliminate the excess of disinfectant e g foam residue over the external surfaces of the device by spraying it w...

Page 14: ...0 C 95 C 194 F 203 F 5 10 minutes Drying 18 22 minutes CAUTION Never cool devices by rinsing them CAUTION If an automatic washer is used at the place of the washer thermo disinfector re spect the prev...

Page 15: ...on is highly dependent on how clean the in strument is Only perfectly clean instruments should be sterilised CAUTION Do not use a sterilisation procedure other than the one described below Procedure C...

Page 16: ...o its use CAUTION Comply with the expiration date of the sterilised items which depends on the storage conditions and type of pack aging 6 7 Servicing Note Bien Air Dental SA recommends that the user...

Page 17: ...s l Damage caused by unusual chem ical electrical or electrolytic influences l Faulty air water or electrical con nections CAUTION The warranty becomes null and void if damage and its consequences res...

Page 18: ...18 NOTES...

Page 19: ...ENG 19 NOTES...

Page 20: ...L nggasse 60 Case postale 2500 Bienne 6 Switzerland Tel 41 0 32 344 64 64 Fax 41 0 32 344 64 91 dental bienair com Other adresses available at www bienair com REF 2100337 0002 2020 06 CA 1 2 5 L MS B...

Reviews: