Regular maintenance ensures the safety and longterm reliability of your gas
warning installation. For this reason it is absolutely essential that the system is
checked at regular intervals. We therefore strongly recommend that you
conclude an installation-specific maintenance contract with us.

Maintenance Instructions

At least once a year the condition (correct operation) of a gas warning
installation must be checked by a qualified person (§8 and §53; BGV 61 UVV
Gases). Before commissioning and at appropriate intervals the gas warning
installation is to be checked by an expert (§56; BGV 61, UVV Gases).

In addition the requirements of BG-Bulletin T023  (BGI 518), Gas warning
devices for explosion protection - selection and operation, must be observed.
Further relevant standards:

DIN EN 60079-14 Electrical apparatus for explosive gas atmospheres -
Electrical installations, design selection and erection

DIN EN 60079-17 Electrical apparatus for explosive gas atmospheres -
Electrical installations, inspection and maintenance.

DIN EN 60079-29-2 Explosive atmospheres - Part 29-2:
Gas detectors - Selection, installation, use and maintenance of detectors
for flammable gases and oxygen

Accessories

Test gas set

Calibration gases

Measurement lead

For all deliveries the general delivery conditions for products and services of
the electrical industry apply.
There is a guarantee on all parts for two years from the delivery date or from
the date of commissioning for the first time by our customer service or by our
representative, with the exception of of parts subject to wear (e.g. sensors).
In particular, please note that in the event of improper operation the right to
notify material defects is forfeited. The time limit for notifying claims for material
defects is 12 months.

Guarantee

Summary of Contents for ExDetector HC 150

Page 1: ...Gas Detection and Warning Systems Operating and Installation Instructions ExDetector HC 150 ExDetector HC 150 K...

Page 2: ...collection point and a possible ignition source Consider the density of the gas For gases with a lower density than air for example methane the detector must be located above a possible leakage point...

Page 3: ...sing in the presence of an explosive atmosphere Terminal Assignment Max outside diameter of cable 10 mm Three core cable with screen Terminal assignment 24VDC 4 20 mA GND 0 4 2V Br N V Br 4 5 6 1 2 3...

Page 4: ...on hazard Ex RL Rules for avoiding dangers from a potentially explosive atmosphere with a collection of examples Explosion Protection Rules Example Connection to GMC8022 Screening The screen is to be...

Page 5: ...or the voltage reading to stabilise Adjust the Br potentiometer until the voltmeter reads 0 mV Setting the base current to 4 mA Connect the voltmeter at the 0 4 2V socket Wait for the 0 4 2V voltage s...

Page 6: ...ing sensor Procedure Switch off the power supply to the detector Remove the housing cover Disconnect the leads from terminals 4 5 and 6 Undo the locknut Unscrew the sensor Screw the replacement sensor...

Page 7: ...ust be observed Further relevant standards DIN EN 60079 14 Electrical apparatus for explosive gas atmospheres Electrical installations design selection and erection DIN EN 60079 17 Electrical apparatu...

Page 8: ...ctor HC 150 HC 150 K Bieler Lang GmbH Gas Detection and Warning Systems PO Box 1129 D 77842 Achern Oberkirchstr 19 21 D 77855 Achern Telephone 49 0 78 41 69 37 0 Telefax 49 0 78 41 69 37 99 E mail inf...

Reviews: