7 MANUFACTURER LIABILITY

The manufacturer and the supplier of the device reject all liability if:

the device is not used in accordance with the instructions for use

the user is not sufficiently informed about the functioning of the device on 
the basis of the instructions for use and the safety instructions

repairs are not performed exclusively by the manufacturer or by persons 
and service centres expressly authorised by the manufacturer

the device is used in places in which the electrical installations do not 
comply with the applicable national standards, or if power supply during 
the period of use of the device is not guaranteed

original spare parts material are not used or the maintenance interval 

is not complied with.

disposal   of   the   device   and   its   accessories   is   not   carried   out   in 

accordance with the applicable local regulations.

8 WARRANTY CONDITIONS

The   manufacturer   guarantees   that   all   flaws   of   material   and   workmanship 
which arise within 24 months from the date of purchase will be repaired free 
of charge.
Claims are only accepted under the following terms:

  

The manufacturer and/or supplier is informed immediately of the fault for 
which the warranty claim is being made.

The instructions of the manufacturer and/or supplier on storage or return 
of the device are complied with.

 

Presentation of a legible copy of the invoice for the device concerned, 
showing the date of purchase.

An   exact   description   of   the   defects   or   malfunctions   identified   by   the 
customer.

16

DE - Edition 02 / 2007

Summary of Contents for BW 685

Page 1: ...Instructions for Use BW 685 BW 685 S Blood and Infusion Warmer...

Page 2: ...Instructions for Use BW 685 BW 685 S BIEGLER DE Edition 02 2007 2 DE Edition 02 2007...

Page 3: ...warnings and safety instructions as well as the instructions for use are read and carefully observed by all users before first using the device It is the responsibility of those using the device to fu...

Page 4: ...3 1 INITIAL OPERATION OF THE DEVICE 9 3 2 ALARMS 12 3 3 SHUTTING DOWN THE DEVICE 12 4 MAINTENANCE 12 5 CLEANING AND DISINFECTION 13 6 PERIODIC INSPECTIONS 14 7 MANUFACTURER LIABILITY 16 8 WARRANTY CO...

Page 5: ...ns in force Safe disconnection from the mains power supply can only be achieved by unplugging the mains plug The device may not be used in rooms subject to explosion hazard Repairs and modifications t...

Page 6: ...d or burns to the patient cannot to be excluded in the case of non compliance Do not shorten or damage the Biegler Tubeflow The BW 685 BW 685 S may not be used if the housing is damaged or one of the...

Page 7: ...nt rails The temperature of the warmer element can be set between 37 C and 41 C in steps of 0 5 C and is clearly displayed The preset temperature after switching on the BW 685 BW 685 S is 38 5 C The a...

Page 8: ...irements For use with BW 685 or BW 685 S without tube warmer Extension set 3 5 m Order no 35000 Extension set 4 6 m Order no 45000 Extension set with bubble trap 4 6 m Order no 25000 For use with BW 6...

Page 9: ...warmer Biegler Tubeflow must be inserted with light pressure as indicated in diagram 3 into the intended fixture Diag 3 4 on the BW 685 S Remove the dust cap from the BW 685 S and attach the connector...

Page 10: ...S attains the set target temperature within 1 minute The actual temperature 0 5 C is indicated on the display Select suitable consumable materials See the section Consumable materials Prepare infusion...

Page 11: ...2007 11 Insert the transfusion or infusion tube into the groove of the tube warmer Insert the tube over the complete length of the Biegler Tubeflow Important Overwarming can result if the full length...

Page 12: ...the power supply Important The temperature alarm can also be set off externally e g by exposure to sunlight 3 3 SHUTTING DOWN THE DEVICE After being used for treatment the device is shut down as foll...

Page 13: ...ECTION The BW 685 BW 685 S and the optional tube warmer Tubeflow may only be cleaned using a soft cloth with a water soluble non aggressive cleaning agent or a special cleaning agent for plastics For...

Page 14: ...eat up to 38 5 C from room temperature The device is malfunctioning if it takes much longer than one minute CHECKING THE CONTROL TEMPERATURE The control temperature is checked on the groove bed of the...

Page 15: ...be triggered at a temperature of 42 C For reasons of safety short beeping sounds are given at intervals of a second in this operational mode and the STANDBY indicator Diag 1 4 flashes There is a malfu...

Page 16: ...guaranteed original spare parts material are not used or the maintenance interval is not complied with disposal of the device and its accessories is not carried out in accordance with the applicable...

Page 17: ...undertaken by persons not authorised by the manufacturer or supplier If the manufacturer is required to meet a warranty claim in accordance with these terms the customer shall bear the costs and risks...

Page 18: ...idelines RF emissions acc to CISPR 11 Group 1 The BW685 uses RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cause any interference in nearby ele...

Page 19: ...surges acc to IEC 61000 4 5 1 kV differential mode 2 kV common mode 1 kV normal mode voltage 2 kV common mode voltage The mains power supply quality should be that of a typical commercial or hospital...

Page 20: ...rotection distance in metres m Field strengths from fixed RF transmitters as determined by an electromagnetic site surveya should be less than the compliance level in each frequency rangeb Interferenc...

Page 21: ...0 MHz P E d 1 5 3 800 MHz to 2 5 GHz P E d 1 7 0 01 0 12 0 12 0 23 0 1 0 37 0 37 0 74 1 1 17 1 17 2 33 10 3 69 3 69 7 38 100 11 67 11 67 23 33 For transmitters rated at a maximum output power not list...

Page 22: ...is product as unsorted municipal waste Control for increasing the temperature setting Control for decreasing the temperature setting IPX 4 Humidity Classes Degree of protection B Control for switching...

Page 23: ...and infusion warmer Type designation BW 685 BW 685 S Voltage 230 V 50Hz Power consumption 1 5 A Protection class I Degree of protection B Humidity protection IPX4 Fuses primary 2 x 1 6 AT secondary 50...

Page 24: ...ns for Use BW 685 BW 685 S BIEGLER 15 MANUFACTURER Biegler GmbH Allhangstrasse 18a 3001 Mauerbach Austria Tel 43 1 979 21 05 Fax 43 1 979 21 05 16 email office biegler com www biegler com 24 DE Editio...

Page 25: ...BIEGLER Instructions for Use BW 685 BW 685 S Space for notes DE Edition 02 2007 25...

Reviews: