19
SUPER VAPOR PLUS/MAGIC VAPOR
4. TECHNICAL DATA
BF072
"SUPER VAPOR PLUS"
BF073
"SUPER VAPOR PLUS"
BF005
"MAGIC VAPOR"
BF002
"MAGIC VAPOR"
Power supply
220/230V 50/60H
220/230V 50/60H
220/230V 50/60H
220/230V 50/60H
Boiler capacity
2,4 Lt
2,4 Lt
2,4 Lt
2,4 Lt
Boiler refill
Manual
Manual
Manual
Manual
Boiler power
900W
900W
1300W
1300W
Boiler pressure
3 bar
3 bar
5 bar
5 bar
Iron power
850W
850W
850W
850W
Colour
White
St. Steel
White
St. Steel
Weight
6,5 Kg
6,5 Kg
30 Kg
23 Kg
Dimensions
24,5×36,5xh22 cm
24,5×36,5xh22 cm
25x36xh30 cm
25x36xh30 cm
5. MACHINE DESCRIPTION
The system consists of a steam generator and a professional iron. For the ironing, in accordance with the
model, it is possible to include a steam generator with an automatic refilling system. Along with all BIEFFE
steam generators, the boiler is made of copper, the heaters are placed outside the boiler so that they are not
immersed in water, allowing to get rid of wear issues and reducing significantly waiting times saving electri
-
city. The best tools on the market as thermostat, pressure switch, safety valve and pressure gauge, check for
the correct functioning of the system automatically.
Before the use we recommend to read carefully all the information related to the model in your possession.
Data, descriptions and illustrations in the following leaflet are not binding. BIEFFE reserves the right to make
any necessary modifications.
6. REGULAR MAINTENANCE: EMPTYING/CLEANING OF THE BOILER
ATTENTION: BEFORE DRAINING THE WATER FROM THE BOILER, UNPLUG THE MACHINE AND UNSCREW
BY HALF A TURN THE SACURITY TAP TO RELEASE THE REMAINING PRESSURE AND HEATH FROM THE
BOILER.
»
Wait for the boiler to be cool and the pressure gauge to show “0”, open carefully the sacurity tap a
turn upside down the steam generator to let the water out. Do this operation on a sink or another water
container.
»
To carry out an extraordinary cleaning, pour into the boiler a glass of vinegar and water. Then shake
the steam generator and empty the boiler and rinse with only water. Do not use any anti-limescale pro
-
duct.
THIS OPERATION MUST BE DONE DEPENDING ON THE USE OF THE MACHINE, AT LEAST ONCE A MON-
TH. IF NOT, THE GUARANTEE WILL DECAY.
7. USABLE WATER
“Boiler volume” means: volume of usable water + steam chamber.
It is normal that the quantity of water inside the boiler is smaller than the boiler volume.
BOILER VOLUME = USABLE WATER STEAM CHAMBER
Boiler volume
Usable water volume
Steam chamber
BF072/BF073
2/2,4 Lt
2,4 Lt
0,5 Lt
BF002/BF005
1,6/2 Lt
1,9 Lt
0,5 Lt
ENGLISH