Electronic control p.c.b.
23
9.11
Thermal control in the ” ” mode
See functioning with the function
control in the
mode
(sec. 9.12)
Taking
water from the domestic hot
water circuit?
Switch in the
function mode
NO
YES
Is primary circuit
temperature higher than that
selected?
NO
Request for heat from
room thermostat?
Starts the circulator
Operates motorised valve
Supplies the ignition device
NO
Circulator off
Operates motorised valve
Ignition device off
YES
YES
Fig. 38
9.12
Thermal control in the ” ” mode
Is domestic
hot water outlet temperature
lower than that
required?
Supplies the ignition device
Ignition device off
Circulator on
YES
NO
Switch in the
function mode
Taking
water from the domestic hot
water circuit?
YES
Circulator off
Ignition device off
NO
Fig. 39