10. Trouble Shooting 

 

 

 

Before inspecting the pump, disconnect the power supply (i.e. remove the plug from 
the socket). If there is any damage to pump or power cable any necessary repairs or 
replacements must be performed by the manufacturer or his authorised customer 
support service, or by an equally-qualified technician. 

 

 

 

Possible cause 

Potential Solution 

The motor does not 
start and there is no 
noise; 

A.  Check the power supply to the 

pump; 
 

B.  Inspect check valve for correct 

installation of blockage; 

Check power supply fuses/circuit 
breakers 

Ensure that the check valve is 
installed correctly and is not 
blocked; 

The pump will not 
start correctly but 
makes a noise 

A.  Possible partial blockage; 

 

B.  Capacitor failure 

 

Pump flow rate is 
poor  

A.  Clogged water inlet filter  

 

B.  Blocked or damaged impellers; 

 

C.  The installation head requirement 

exceeds the pump potential 

 
Clear the blockage; 
 
Remove obstacles or replace the 
impellers 

Water doesn’t flow 
when a tap is closed 
and reopened 

A.  Inspect the check valve for 

blockage 

Reinstall the check valve to ensure 
that there is no blockage; 

The flow has 
decreased over time 

A.  Partial blockage of the water inlet 

filter; 
 

B.  The impeller is partially blocked 

or the outlet pipe is partially 
blocked; 

Remove obstacles 

The pump runs for a 
period of time then 
switches off 
unexpectedly.  

A.  The thermal overload protection 

device may have operated to stop 
the water pump automatically. 

The fluid density or fluid 
temperature may be too high 
causing the motor to overheat: 

A small water demand may be 
causing the pump to start and stop 
excessively 

 

 

 

 

Summary of Contents for BIA - AUTOSUB

Page 1: ...Bianco Pumpz BIA AUTOSUB User Manual 1 BIA AUTOSUB User Manual ...

Page 2: ... Standards and Approvals SAA Approvals is accredited by the Joint Accreditation Service of Australia and New Zealand JAS ANZ as a third party certification body to issue of Certificates of Approval for declared and non declared electrical equipment that has proven to comply with the safety requirements of the applicable Australian Standard CE marking is a certification mark that indicates conformi...

Page 3: ...general drainage applications Any changes or modification to the wiring must be carried out by suitably qualified personnel If the appliance or the supply cord is damaged it must be repaired by manufacturer its service agent or qualified person A qualified electrician should correctly size and install circuit breakers to protect the power supply The fitment of additional surge protection is recomm...

Page 4: ...P68 Max 12m immersion Working Temperature Air 5 to 40 C Water 3 C to 35 C Max Dia of Particle Slotted Strainer Max 1mm particles Packaging gross weight kg 9KG Max Flow lpm 100lpm Max Head m 45m Pump Control and Protection iSENSOR Auto Control Fixed Arm Float Switch 5 ISO 7010 Symbols used in this manual Warning Electrical safety Warning Potential consequences of use outside of intended application...

Page 5: ...ump It should be repaired or replaced by professional or authorized personnel 6 Note that the length of the pump s power cord is intended to limit the pump submersion depth of the pump 7 The pump is not allowed to be used in occasions where people are in the water 8 Ensure sure that the plug and socket of the plug cord are kept dry 7 Installation The pump must be tied with a rope to the handle bef...

Page 6: ...ng down 2 No load Dry run protection There is a 3 second delay to the pump starting after powering on If there is no water present the pump will run for 30 seconds then stop for 5 seconds This cyle 30 seconds run 5 second stop repeates three times After the third cycle the pump will suspend its operation for 24 hours To avoid frequent and unnecessary pump restarts to achieve greater energy savings...

Page 7: ...water pump before maintenance and cleaning Should the pump ingest sediment it is strongly recommended to flush the pump in clear water 1 Use a screwdriver to unscrew the eight screws 2 Remove the base from the pump 3 Remove the filter and bracket from the pump respectively 4 Clean the impurities on the base filter and bracket 5 After cleaning install the bracket on the water pump and install the f...

Page 8: ...ossible partial blockage B Capacitor failure Pump flow rate is poor A Clogged water inlet filter B Blocked or damaged impellers C The installation head requirement exceeds the pump potential Clear the blockage Remove obstacles or replace the impellers Water doesn t flow when a tap is closed and reopened A Inspect the check valve for blockage Reinstall the check valve to ensure that there is no blo...

Page 9: ...nd Consumer Act 2010 Cth for goods purchased in Australia and the Consumer Guarantees Act 1993 NZ for goods purchased in New Zealand 4 Our goods come with guarantees that cannot be excluded under the Australian Consumer Law You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage You are also entitled to have the goods...

Page 10: ...10 Bianco Pumpz BIA AUTOSUB User Manual ...

Page 11: ...Bianco Pumpz BIA AUTOSUB User Manual 11 ...

Page 12: ...n product specifications 2020 Copyright White International Pty Ltd TM WARNING Please be aware that various brands products depicted within this document are subject to trademark patent or design registrations Infringement of any intellectual property contained within this document without express written authority by the appropriate intellectual property holder may result in further legal action ...

Reviews: