5.1 Cautions

 

 

5.1.1  Protect the pump and controller from rain and moisture and minimise exposure to 

extremes of heat and cold. Operating range 2

o

C - 40

o

C. 

5.1.2  The pump is designed for use with clean water. Contamination including sand or 

mineral deposits may affect the operation of the pump and controller. 

5.1.3  The pH of the water must be between 6.5 and 8.5. 

5.1.4  This pump is not suitable for use with spa or pool water. 

5.1.5  Running the pump without water or allowing the pump to run dry will damage the 

mechanical seal and void the warranty.  

5.1.6  Avoid situations where the pump could be exposed to corrosive liquids or gasses, or 

to flammable materials, solvents etc. 

5.1.7  Fitment and replacement must be carried out by competent, skilled and qualified 

personnel. 

6. Standards and Approvals

 

 

 

 

SAA Approvals

 is accredited by the Joint Accreditation 

Service of Australia and New Zealand (JAS-ANZ) as a third 
party certification body to issue of Certificates of Approval for 
declared and non-declared electrical equipment that has 
proven to comply with the safety requirements of the 
applicable Australian Standard. 

 

Pumps that carry the AS/

NZ4020 Drinking Water Approval

 

demonstrate compliance with requirements of Australia & 
New Zealand Standards of products that come into contact 
with water intended for human consumption. This approval 
also ensures that the water coming from the pump will not be 
contaminated by toxic materials or metals. It also means the 
water will not support the growth of micro-organisms and will 
not cause a change in taste or appearance. 

 

CE marking

 is a certification mark that indicates conformity 

with health, safety and environment. The CE marketing 
represents a manufacturer’s declaration that products comply 
with the EU’s New Approach Directives. These directives not 
only apply to products within the EU but also for products that 
are manufactured in or designed to be sold in the EEA. 

 

 

Summary of Contents for 808393

Page 1: ...1 ntroller Pumps INOX45 808393 INOX60 808394 INOX90 808395 FERRO60 808397 PTF 808396...

Page 2: ...s equally comfortable pumping from a tank boosting low pressure water supply or working in conjunction with a rainwater changeover device PTF peripheral turbine pumps are best suited to flooded suctio...

Page 3: ...mains supply or connecting to a hot water system 10 12 Water supply above the pump inlet flooded suction 11 13 Water supply below the pump inlet suction lift 12 14 Priming and Operation 13 15 Warrant...

Page 4: ...urge protection is recommended Never open the controller cover or pump terminal box cover while controller is connected to electrical supply This appliance is not intended for use by persons including...

Page 5: ...e of Australia and New Zealand JAS ANZ as a third party certification body to issue of Certificates of Approval for declared and non declared electrical equipment that has proven to comply with the sa...

Page 6: ...Motor Insulation Motor Rating KW 0 45kW 0 6kW 0 9kW 0 6kW 0 37kW HP 0 6hp 0 8hp 1 2hp 0 8hp 0 5hp Max Amperage 3 5 amps 4 amps 6 amps 4 5 amps 2 5 amps Start Capacitor 10 uF 16 uF 25 uF 12 uF 8 uF Pu...

Page 7: ...uired by Australian New Zealand Standard AU NZS 60335 1 2011 The pump is supplied with a 10 amp rated lead and AS NZ 3112 Type I 3 pin male power plug for connecting to mains power Exercise care with...

Page 8: ...hould be housed in a weather proof free draining well vented enclosure to protect it from the extremes of temperature moisture flooding chemicals vermin and insects dust etc Before installation inspec...

Page 9: ...results in air pockets Connection to the pump using unions ensures easy removal for servicing If the water supply is above the pump inlet fit an isolating valve close to the pump A gate valve on the...

Page 10: ...the guidelines in Section 12 or 13 depending whether the water from the tank will be above or below the pump inlet Note PTF models not recommended for suction lift applications Pumps supplying Mains P...

Page 11: ...inders of best practice Fit a valve to isolate the tank If the suction line is quite long fit another valve close by the pump Non Return Valve in suction line recommended Avoid pipework which could tr...

Page 12: ...ove the intake at all times Keep the intake screen at least 100mm above the bottom of the tank or well Avoid pipework which could trap air Use the Suction Pipe Recommendation chart to select the corre...

Page 13: ...th clean water via the priming port or by removing the controller see controller instructions Check that the motor fan blade rotates freely Ensure that the pump inlet line is fully submerged and that...

Page 14: ...0 Cth for goods purchased in Australia and the Consumer Guarantees Act 1993 NZ for goods purchased in New Zealand 4 Our goods come with guarantees that cannot be excluded under the Australian Consumer...

Page 15: ...repair 6 Clean any filters strainers in the system 7 Contact your pump professional The pump runs There is flow but poor pressure 1 Excessive flow demand 2 Total head requirement too great for the pum...

Page 16: ...tions 2020 Copyright White International Pty Ltd TM WARNING Please be aware that various brands products depicted within this document are subject to trademark patent or design registrations Infringem...