background image

 

 

VA-8150CV / VA-4300CV Front 

 

System Indicators 

The LED indicators on the front panel of the amplifier provide information and operational status of the 
amplifier and its associated output channels. LED layout and features vary between amplifier models. 
LED’s are grouped to show chassis status indication and amplifier channel status indication. Please see 
the Front Panel View section for details on the different configurations between the various amplifier 
models. 

Amplifier Chassis Indicators 

These indicators relate to the entire amplifier unit (chassis). 

AC Power 

AC power is a green LED indicator. This will illuminate when a Mains supply is applied to the unit. 

DC Power 

DC Power is a green LED indicator. This illuminates when an auxiliary DC supply is applied to the unit via 
either or both Auxiliary power inputs. 

CAUTION 

Refer to the caution in the Rear Panel Auxiliary Power section 

Amp Fault 

An amber LED illuminates when a chassis fault has occurred. 

 

Flashing Amber LED

 - Warning -the amplifier chassis is not operating within normal limits. If the 

condition causing the Warning is not corrected, chassis failure may occur. 

 

Solid Amber LED

 - Fault - the amplifier chassis has failed - audio may have stopped. 

Activity 

Activity indicates the configuration status of the Amplifier. 

 

LED off

 - the unit is not active. 

 

Green LED

 - the unit is configured. 

 

Flashing Amber LED

 - the unit is active but has no configuration. 

 

Amber LED

 - the unit is configured as a redundant device in a failover configuration. 

 

Red LED

 - indicates a configuration load failure. 

Status 

Status indicates the health of the amplifier hardware. 

 

Green LED

 - indicates that the unit powered up normally. 

 

Amber Flashing LED

 - shown briefly during the power-up self-test. 

 

Red LED

 - the unit experienced a problem during the power-up self-test. 

Summary of Contents for Vocia VA-4300CV

Page 1: ...VA 8150CV and VA 4300CV OPERATION MANUAL 0D 585 0406 900...

Page 2: ...r inputs The VA 4300CV also has comprehensive failover capability with device to device and channel to channel failover The VA 8150CV is a digital networked eight channel constant voltage 70V 100V amp...

Page 3: ...inch 88 9mm high and 19 inch 483mm wide rack space with 17 5 inch 444mm depth Mounting the unit using four screws with washers will prevent marring of the front panel PVC or nylon washers are appropri...

Page 4: ...th Auxiliary power inputs CAUTION Refer to the caution in the Rear Panel Auxiliary Power section Amp Fault An amber LED illuminates when a chassis fault has occurred Flashing Amber LED Warning the amp...

Page 5: ...nel for failover applications Amber flashing LED the amplifier channel has failed or there is a speaker line fault and audio may have stopped Signal The Signal LED will illuminate when the amplifier o...

Page 6: ...s required to operate without a DC supply the Auxiliary supply fault monitoring must be disabled in Vocia software A loss of supply fault is indicated via the Vocia software and by a blinking amber Am...

Page 7: ...e CobraNet fault Check cabling and configuration for errors Device ID Switches The VA 8150CV and VA 4300CV units represent separate Vocia device types The rotary ID switches give the unit a unique Dev...

Page 8: ...orts Use of the supplied cable restraints is required to secure the cable in the connector To facilitate parallel wiring each connector allows for the connection of two loads to each amplifier channel...

Page 9: ...ary amplifier Loss of Failover Link connection ELD 1 PLD 2 speaker line fault if enabled in software Only faults Chassis and Channel trigger the failover mechanism Abnormal conditions that do not imme...

Page 10: ...Speaker Redundant Speakers Failover Channel 3 1 and 7 1 Failover The VA 4300CV amplifier supports 3 1 channel redundancy This is configured in the Vocia Software in the amplifiers general setting as 3...

Page 11: ...3 3 1 7 4 Burst mode only Protective thermal limiting will reduce long term AC current and continuous power output AC current draw for 100V operation TOTAL OUTPUT POWER Watts CONFIGURED CHANNELS IDLE...

Page 12: ...6 NA NA NA 150 1 0 9 1 3 2 4 4 300 2 1 1 2 3 7 8 2 450 3 1 4 2 7 5 4 12 2 600 4 1 7 3 5 7 2 16 2 750 5 1 9 4 3 8 8 20 1 900 6 2 2 5 1 10 5 24 1 1050 7 2 5 5 9 12 3 28 1 1200 8 2 7 6 7 13 9 32 2 VA 430...

Reviews: