VA-8150CV and VA-4300CV 

OPERATION MANUAL 

0D\

 

585.0406.900 

Summary of Contents for Vocia VA-4300CV

Page 1: ...VA 8150CV and VA 4300CV OPERATION MANUAL 0D 585 0406 900...

Page 2: ...r inputs The VA 4300CV also has comprehensive failover capability with device to device and channel to channel failover The VA 8150CV is a digital networked eight channel constant voltage 70V 100V amp...

Page 3: ...inch 88 9mm high and 19 inch 483mm wide rack space with 17 5 inch 444mm depth Mounting the unit using four screws with washers will prevent marring of the front panel PVC or nylon washers are appropri...

Page 4: ...th Auxiliary power inputs CAUTION Refer to the caution in the Rear Panel Auxiliary Power section Amp Fault An amber LED illuminates when a chassis fault has occurred Flashing Amber LED Warning the amp...

Page 5: ...nel for failover applications Amber flashing LED the amplifier channel has failed or there is a speaker line fault and audio may have stopped Signal The Signal LED will illuminate when the amplifier o...

Page 6: ...s required to operate without a DC supply the Auxiliary supply fault monitoring must be disabled in Vocia software A loss of supply fault is indicated via the Vocia software and by a blinking amber Am...

Page 7: ...e CobraNet fault Check cabling and configuration for errors Device ID Switches The VA 8150CV and VA 4300CV units represent separate Vocia device types The rotary ID switches give the unit a unique Dev...

Page 8: ...orts Use of the supplied cable restraints is required to secure the cable in the connector To facilitate parallel wiring each connector allows for the connection of two loads to each amplifier channel...

Page 9: ...ary amplifier Loss of Failover Link connection ELD 1 PLD 2 speaker line fault if enabled in software Only faults Chassis and Channel trigger the failover mechanism Abnormal conditions that do not imme...

Page 10: ...Speaker Redundant Speakers Failover Channel 3 1 and 7 1 Failover The VA 4300CV amplifier supports 3 1 channel redundancy This is configured in the Vocia Software in the amplifiers general setting as 3...

Page 11: ...3 3 1 7 4 Burst mode only Protective thermal limiting will reduce long term AC current and continuous power output AC current draw for 100V operation TOTAL OUTPUT POWER Watts CONFIGURED CHANNELS IDLE...

Page 12: ...6 NA NA NA 150 1 0 9 1 3 2 4 4 300 2 1 1 2 3 7 8 2 450 3 1 4 2 7 5 4 12 2 600 4 1 7 3 5 7 2 16 2 750 5 1 9 4 3 8 8 20 1 900 6 2 2 5 1 10 5 24 1 1050 7 2 5 5 9 12 3 28 1 1200 8 2 7 6 7 13 9 32 2 VA 430...