The EX-UBT device will reboot itself implementing the USB Device Name change and the host computer* will update
with the new USB Device Name:
*(This feature had mixed results when tested on Mac OSX using 1-7 channel USB block. 8 channel EX-UBT USB block reportedly worked well.)
When the EX-UBT blocks are initialized as a speakerphone and selected as the Default Audio Device in the Windows 10
host computer, mute and volume synchronization occurs upon USB connection. This means that the host computer
volume level will synchronize with the volume level of the EX-UBT USB input block in the Tesira configuration. Volume
and mute changes made on the host computer or the EX-UBT USB input block will remain synchronized. This behavior
is demonstrated in this short
. Note that files created with Tesira 3.17 or newer will set the USB block minimum
level to -50 in order to map more accurately to the host PC volume ramp range and rate. This
demonstrates the Tesira 3.17 behavior.
When privacy mute is selected in Skype For Business*, Microsoft Teams Room System* or Google Hangouts Meet
System*, the mute state of the EX-UBT Output block mute will track accordingly. Similarly, if the mute logic input of the
EX-UBT USB Output block is triggered high, the privacy mute indication in Skype For Business or Microsoft Teams will
follow.
Copyright 2013-2020 Biamp Systems
http://support.biamp.com/
9