Biamp Tesira EX-UBT Manual Download Page 9

The EX-UBT device will reboot itself implementing the USB Device Name change and the host computer* will update
with the new USB Device Name:

*(This feature had mixed results when tested on Mac OSX using 1-7 channel USB block. 8 channel EX-UBT USB block reportedly worked well.)

When the EX-UBT blocks are initialized as a speakerphone and selected as the Default Audio Device in the Windows 10
host computer, mute and volume synchronization occurs upon USB connection. This means that the host computer
volume level will synchronize with the volume level of the EX-UBT USB input block in the Tesira configuration. Volume
and mute changes made on the host computer or the EX-UBT USB input block will remain synchronized. This behavior
is demonstrated in this short

video

. Note that files created with Tesira 3.17 or newer will set the USB block minimum

level to -50 in order to map more accurately to the host PC volume ramp range and rate. This

example video

demonstrates the Tesira 3.17 behavior.

When privacy mute is selected in Skype For Business*, Microsoft Teams Room System* or Google Hangouts Meet
System*, the mute state of the EX-UBT Output block mute will track accordingly. Similarly, if the mute logic input of the
EX-UBT USB Output block is triggered high, the privacy mute indication in Skype For Business or Microsoft Teams will
follow.

Copyright 2013-2020 Biamp Systems

http://support.biamp.com/

9

Summary of Contents for Tesira EX-UBT

Page 1: ...A standard USB cable connects the host computer to the EX UBT CAT5e cabling or better is required for the network connection with a maximum distance of up to 100 meters 328 ft allowed to the equipment...

Page 2: ...hen configured as a speakerphone the EX UBT uses Human Interface Device HID communication that can synchronize privacy mute state and volume control if the UC application supports this communication H...

Page 3: ...allows the following codecs to be received SBC Qualcomm aptX audio AAC Bluetooth pairing may also be made via pre configured Near Field Communication NFC tags NFC tags allow users with NFC capable ena...

Page 4: ...Software programming Configurations for the Tesira EX UBT are available from the Object Toolbar via the Telephony Communications menu item When the Tesira EX UBT object type is selected from the Audio...

Page 5: ...to eight channels of audio Combinations of 2 4 6 or 8 total USB channels can operate in fixed 24 Bit 48 kHz Mute USB inputs as a group Selecting this mutes all USB input channels when the mute state o...

Page 6: ...DSP blocks The following images show the DSP blocks associated with different Initialization options Copyright 2013 2020 Biamp Systems http support biamp com 6...

Page 7: ...For more details regarding EX UBT logic please reference tesira help biamp com Copyright 2013 2020 Biamp Systems http support biamp com 7...

Page 8: ...ck initialization Notice the sound device name also includes the unique serial number of the EX UBT device by default If the user would like to change the name of the EX UBT device as it presents to t...

Page 9: ...figuration Volume and mute changes made on the host computer or the EX UBT USB input block will remain synchronized This behavior is demonstrated in this short video Note that files created with Tesir...

Page 10: ...of level and mute states is possible via USB HID communication Performance may vary with applications not listed in the UC compatibility table EX UBT USB Tips Copyright 2013 2020 Biamp Systems http s...

Page 11: ...and can be customized via the Edit button Inactivity Timeout An active Bluetooth connection will be disconnected after the defined time period When set to 0 seconds a connection will not timeout Bluet...

Page 12: ...tivity Timeout to 0 seconds will allow a connected Bluetooth host to remain connected indefinitely Be sure to test various sources and applications because the Streaming indication may vary with each...

Page 13: ...el dBu signals in the Tesira configuration consider using attenuation or dynamics to level match these different source types The EX UBT Bluetooth input block does include a Peak indication LED This i...

Page 14: ...available at tesira help biamp com Troubleshooting General When troubleshooting HID mute synchronization on various UC clients and hardware iterations it is often helpful to test and compare the mute...

Page 15: ...ble validation of connected channels Note that a 12dBu signal from the Tesira tone generator to a USB meter should indicate about 12dBFS 3rd party audio metering software can be used to independently...

Reviews: