Tesira Amplifier Specifications 

 

Specification Table 

Connection: 

  

Ethernet Control  Input 

Single RJ45 with shielded Ethernet  

cable (CAT5, 5e, 6 or 7) 

AVB / TSN Input 

Dual RJ45 with shielded Ethernet  

cable (CAT5, 5e, 6 or 7) 

  

  

 

Dimensions

  

Height: 

3.5 Inches (88.9mm) 

Width: 

19 Inches (483mm) 

Depth: 

17.4 Inches (441mm) 

Weight: 

20.6lbs (9.3 kg) 

  

 Power 

  

AC 

100V-240V, 50Hz /  60 Hz 

 8175R, 4350R and 4300R CV 

3A - 2.2A 

4175R 

2A 

– 2A 

  

Environment: 

  

Cooling 

Variable speed fan 

Ambient Operating Temperature 

18-108°F 

  

 (-8-42°C) 

Humidity 

0 - 95%  

Altitude 

0 - 10000 Feet MSL  

  

(0 - 3000 Meters MSL)  

  

Compliance: 

  

  

UL Listed- USA and Canada E305194 

  

FCC Part 15 Subpart B class A 

  

CE Marked 

  

RCM Marked 

  

EAC Marked  

  

RoHS Compliant 

  

CCC 

  

KCC 

 

  

Tesira AMP-8175R Audio Specification 

Output Channels: 

Maximum Rated Output 

  

Single Channel Driven, 4Ω, 8Ω 

175W 

Bridged 

8Ω 

350W (Time Limited) 

Minimum operating load 

2

Ω 

    

Tesira AMP-4350R Audio Specification 

Output Channels: 

Maximum Rated Output 

  

Single Channel Driven, 4Ω, 8Ω 

350W 

Bridged 

8Ω 

700W (Time Limited) 

Minimum operating load 

2

Ω 

 

Common Audio Specification 

  

Frequency Response (20Hz to 20kHz): 

+ - 1dB,  

THD+N (20Hz to 20kHz @ rated power): 

<0.3% 

Dynamic Range 

>100dB 

20Hz - 20kHz 

 

Tesira AMP-4175R Audio Specification 

Output Channels: 

Maximum Rated Output 

  

Single Channel Driven, 4Ω, 8Ω 

175W 

Bridged 8Ω 

300W (Time Limited) 

Minimum operating load 

2

Ω 

  
  

Tesira AMP-4300R CV Audio Specification 

Output Channels: 

Maximum Rated Output 

  

Single Channel Driven, 70V/100V 
(Constant Voltage) 

300W 

  

 
 
 
Audio IO 

  

Supported cards Tesira EXMOD EIC-4, EIOC-4 or EOC-4  

8 channel amplifier 

2 cards (optional) 

4 channel amplifier 

1 card (optional) 

Note:

 For failover purposes, installed card must have at least 

one input channel available (EIC-4 or EIOC-4) 

  

  

 

Summary of Contents for Tesira AMP-4175R

Page 1: ...AMP 4175R AMP 4300R CV AMP 4350R and AMP 8175R OPERATION MANUAL 585 0407 900 MAY 2016...

Page 2: ...nnel mute or all channels mute and provides feedback on overall status and channel performance All models feature impedance monitoring as well as dual AVB TSN connections for network redundancy Option...

Page 3: ...uires one 3 5 inch 88 9mm high and 19 inch 483mm wide rack space with 17 5 inch 444mm depth Mounting the unit using four screws with washers will prevent marring of the front panel Install the unit aw...

Page 4: ...ed output channels LED layout and channel meters vary between amplifier models LED s are grouped to show chassis status indication and amplifier channel status indication 1 Air Vent Grille 2 Channel s...

Page 5: ...the ground prong on the power cord as this will constitute a shock hazard Equipment should be connected to a mains socket outlet with a protective earthing connection This plug is the main disconnecti...

Page 6: ...to the connector as stray strands can short to the adjacent terminal or chassis Do not leave excessive bare wire outside the terminals as this can lead to shorts Use of the supplied cable restraints i...

Page 7: ...um Rated Output Single Channel Driven 4 8 175W Bridged 8 350W Time Limited Minimum operating load 2 Tesira AMP 4350R Audio Specification Output Channels 4 Maximum Rated Output Single Channel Driven 4...

Page 8: ...Notes Page...

Page 9: ...t comply with all local codes National Electrical Code ANSI NFPA 70 for United States Canadian Electrical Code Part 1 CSA C22 1 Sections 2 128 12 010 3 and 12 100 for Canada Wall Mounting Instructions...

Page 10: ...ente o si se ha ca do ADVERTENCIA Para reducir el riesgo de incendio o descarga el ctrica no exponga estos productos a la lluvia o humedad Estos productos no deben exponerse a goteos o salpicaduras ni...

Page 11: ...position du produit l humidit ou la pluie fonctionnement anormal du produit chute du produit etc AVERTISSEMENT Pour limiter les risques d incendie ou d lectrocution n exposez pas ce produit l humidit...

Page 12: ...Umgebung gestanden ist sich nicht erwartungsgem verh lt oder wenn es gefallen ist ACHTUNG Um das Risiko eines Brandes oder eines elektrischen Schlages zu vermeiden das Ger t vor Regen und Feuchtigkeit...

Page 13: ...1 2 3 4 5 6 7 8 9 10 11 12 13 14 100 POTS 26 AWG Biamp Biamp ANSI NFPA 70 1 CSA C22 1 2 128 12 010 3 12 100 4 2...

Page 14: ...1 2 3 4 5 6 7 8 9 10 11 12 13 14 100 V Hazardous Live MAINS MAINS MAINS MAINS POTS 26 AWG Biamp Biamp AC MAINS ANSI NFPA 70 Part 1 CSA C22 1 Sections 2 128 12 010 3 12 100 4 2 2...

Page 15: ...Fuses 1 2 3 4 5 6 7 8 9 10 11 12 13 14 100 12 100 12 010 2 128 1 4 POTS AWG 26 Biamp Biamp Drywall ANSI NFPA 70 CSA C22 1 3...

Page 16: ...perar normalmente ou se tiver ca do AVISO Para reduzir o risco de inc ndio ou choque el trico n o exponha esses produtos chuva ou umidade Estes produtos n o devem ser expostos a goteiras ou respingos...

Page 17: ...1 2 3 4 5 6 7 8 9 10 11 12 13 14 100 POTS 26 AWG Biamp Biamp ANSI NFPA 70 1 CSA C22 1 2 128 12 010 3 12 100 4 2 1 5...

Page 18: ...ommercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to rad...

Page 19: ...al and Paper Documents O O O O O O Box and Packing Materials O O O O O O Ethernet Crossover Cable O O O O O O 0 SJ T11363 2006 X SJ T11363 2006 0 01 91 338 EEC 76 769 EEC 0 1 1 2 0 35 3 0 4 4 4 5 85 6...

Page 20: ...ll become the property of Biamp Systems 4 This warranty will be VOID if the serial number has been removed or defaced or if the product has been altered subjected to damage abuse or rental usage repai...

Reviews: