background image

 

BLOCK DIAGRAM & SPECIFICATIONS 

 
 

HPF 180Hz

18dB/octave

Out

Gnd

+

D60EQ Block Diagram

Input

-

In

HPF

Level

Driver

Amplifier

Common

Power

Amplifier

Balanced
input Stage

Signal

Detect

Peak

Signal

Present

4

Ω

 Out

Xfmr In

8

Ω

 Out

70V Out

100V Out

Distribution
Autoformer

Output

9-band graphic equalizer

64 125 250 500 1k 2k 4k 8k 16k

 

 
 
 

_________________________________  

SPECIFICATIONS  

_________________________________ 

 

AMPLIFIER SECTION:

 

Output Power (2kHz @ 0.2% THD) 

>60 watts

Frequency Response (20Hz-20kHz @ 60W) 

+0/-1.5dB

Total Harmonic Distortion (20Hz-20kHz @ 60W) 

<0.2%

Intermodulation Distortion (SMPTE) 

<0.35%

Signal-to-Noise Ratio (20Hz-20kHz @ 60W) 

>89dB

Input Sensistivity 

.775 Volts 

Input Impedance 

 balanced 

 unbalanced 

20k ohms

10k ohms

INTERNAL AUTOFORMER:

 

Frequency Response (150Hz-20kHz @ 60W/70V output) 

+0/-3dB

Total Harmonic Distortion (2kHz @ 60W/70V output) 

<0.2%

EQUALIZER SECTION: 

Filter Gain 

+/-15dB

Center Frequencies 

64Hz, 125Hz, 250Hz, 

500Hz, 1kHz, 2kHz,

4kHz, 8kHz, 16kHz

Power Requirements 

115/230VAC  50/60Hz

Power Consumption 

160 watts max.

Dimensions 

  Height (2 rack spaces) 

 Width 

 Depth 

3.5 inches (89mm)

10.2 inches (259mm)

11.4 inches (290mm)

Weight 15 

lbs. 

(6.81kg)

 

Summary of Contents for D60EQ

Page 1: ...blank D60EQ Amplifier Equalizer Operation Manual Biamp Systems 9300 S W Gemini Drive Beaverton OR 97008 USA 1 503 641 7287 www biamp com...

Page 2: ...19Mar07...

Page 3: ...EQ features include integrated equalizer amplifier and distribution autoformer electronically balanced differential line level input stage 9 band graphic equalizer 15dB on ISO center frequencies 60W o...

Page 4: ...ided for your safety When the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet Protect the power cord from being walked on or pinched particula...

Page 5: ...3...

Page 6: ...4...

Page 7: ...5...

Page 8: ...z should not be boosted see Output Barrier Strip on next page 2 Level Control The level control determines the amplitude of the output signal 3 On Indicator This green LED indicates that AC power is o...

Page 9: ...operation use a T 2A L 250V fuse For 230 volt operation use a T 1A L 250V fuse 4 Output Barrier Strip The output barrier strip provides connections for the output of the amplifier The Common terminal...

Page 10: ...ter is enabled When the strap is in the OUT down position the filter is disabled To avoid high magnetization currents which cause the amplifier to current limit and distort the output signal when low...

Page 11: ...quency Response 20Hz 20kHz 60W 0 1 5dB Total Harmonic Distortion 20Hz 20kHz 60W 0 2 Intermodulation Distortion SMPTE 0 35 Signal to Noise Ratio 20Hz 20kHz 60W 89dB Input Sensistivity 775 Volts Input I...

Page 12: ...repairs or installed in any manner that does not comply with BIAMP Systems recommendations 4 Electro mechanical fans electrolytic capacitors and normal wear and tear of items such as paint knobs hand...

Page 13: ......

Reviews: