background image

 A: 

9300 S.W. Gemini Drive Beaverton, OR 97008 USA 

 

T:

 +1 503.641.7287  

W: 

www.biamp.com

JUNE 2019

3.    Locate

Pressing the locate button will play an audible signal that cycles through 

each connected output. 

4. Amp Status 

A multi-color LED provides information about the status of the amplifier.

Status

LED Indicator

No Power

Off

Clip detected

Red Solid

Amplifier limiter engaged

Yellow Solid

Powered

Green Solid

Amplifier is in Locate mode (triggered from the software)

Green Flashing

Amplifier has failed to initialize, an error is present, or the 

amp is temporarily muted due to an audio burst

Red Flashing

PoE+ power is not available or insufficient to power the 

amplifier so it has been turned off

Red/Yellow Flashing

5.   Outputs 1-4

RJ-45 speaker connections. 4 x 3W RMS or 2 x 7W RMS or 1 x 15W RMS 

output at low impedance 4Ω/8Ω.

Front Panel and Connectors

1.   AVB/Control

Facilitates connection to the Tesira AVB network for audio and control. This 

RJ-45 port may either be connected directly to the Tesira AVB port (via a 

PoE+ injector) for a single device system or via a PoE+ network switch in a 

multi-device AVB system. IEEE 802.3at Power over Ethernet Plus (P0E+) 

Class 4 is required as there are no other provisions for power inlet.

2.   Power/System LED Status Indicator

A multi-color LED provides information about the status of the device

Status

LED Indicator

No Power

Off

Powered but not ready to receive configuration

Red Solid

Ready to receive configuration or updating firmware

Yellow Solid

Configured and ready to participate in the system

Green Solid

Amplifier is in Locate mode (triggered from the software)

Green Flashing

Unit has a Major Alarm condition

Red Flashing

Unit has a Minor Alarm condition

Yellow Flashing

Unit has both a Major and Minor Alarm condition

Red/Yellow Flashing