Biamp ALC-1604AN Installation & Operation Manual Download Page 1

A:

 9300 Gemini Drive, Beaverton, OR 97008                                                                                                               

W:

 www.biamp.com

MODELS

ALC-404D
ALC-1604D
ALC-3202D

       

COMMUNITY

AMPLIFIED LOUDSPEAKER CONTROLLERS

  Installation & Operation Guide

Packing List

The box contains the following:

1x ALC-3202 (D or AN model)  

     (Phoenix connectors plugged in)

1x Phoenix MC 1,5/4-ST-3,81 - 1803594 plug

3x Phoenix MC 1,5/6-ST-3,81 - 5447900 plug

1x Phoenix PC 5/4-STF1-7,62 - 177859 plug

3x IEC power cord

1x Safety guide

OR

1x ALC-404 or ALC-1604 (D or AN model)  

     (Phoenix connectors plugged in)

1x Phoenix MC 1,5/4-ST-3,81 - 1803594 plug

3x Phoenix MC 1,5/12-ST-3,81 - 1803675 plug

1x Phoenix PC 5/8-STF1-7,62 - 177891 plug

3x IEC power cord

1x Safety guide

In an effort to reduce the quantity of printed material while 

enhancing the quality of content, we have decided to adopt 

a new approach for the production of this quick guide. The 

safety  and  regulatory  information  is  included  in  the  box 

along  with  a  QR  code  directing  the  installer/user  to  this 

Installation and Operation Guide pdf available on Biamp's 

website.  
Vital information descriptions have been condensed in two 

pages, and all illustrations and tables follow. Each section's 

color bar (ex. 

)

  refers to the outlined area on front or rear 

panel of the ALC image and the corresponding information 

tables.  Call-out  bubbles 

1

/

A

  guide  you  to  specific 

elements of those sections.
Please take time to read and understand all warnings and 

safety instructions on the next few pages of this manual. 
ArmoníaPlus  is  a  trademarked  control  software  product 

from Powersoft S.p.A. 

Additional important information regarding ArmoníaPlus 

software and networking setup is explained in this 

Cornerstone 

article

.

ALC-404AN
ALC-1604AN
ALC-3202AN

Connecting people through extraordinary audiovisual experiences™

Summary of Contents for ALC-1604AN

Page 1: ...pt a new approach for the production of this quick guide The safety and regulatory information is included in the box along with a QR code directing the installer user to this Installation and Operati...

Page 2: ...RMITY WITH DIRECTIVE 2012 19 EC OF THE EUROPEAN PARLIAMENT ON WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT WEEE Safety Warnings 35 C 0 C OPERATING TEMPERATURE RANGE 0 C TO 35 C DERATING ABOVE 35 C 10 85...

Page 3: ...SS3 WIRING CET QUIPEMENT DOIT TRE MONT UNE HAUTEUR MAXIMALE DE 2 M CLASS3 WIRING LE FABRICANT NE PEUT TRE TENU POUR RESPONSABLE DES DOMMAGES CAUS S AUX PERSONNES OBJETS OU DONN ES DUS UNE CONNEXION LA...

Page 4: ...ed and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules This equipment generates uses and can radiate radio frequency energy and if not installed and u...

Page 5: ...ified Loudspeaker Controller ALC in well ventilated rack cabinets Secure both front and rear brackets to the rack Connect the AC Mains connector to a circuit breaker Install the ALC far from EMF emitt...

Page 6: ...short ALC is in Standby All ALCs feature further monitoring on pilot tone and output load through Armon aPlus System Manager Self Check The self check procedure tests the ALC status and reports the us...

Page 7: ...Amplified Loudspeaker Controller Install and User Guide 7 Location Cooling 1 1 1 RU 1 RU 1 RU 1 1 2 2 2 2 3 3 3 3 4 4 4 4 5...

Page 8: ...er Controller Install and User Guide Exposing the Control Panel Dimensions Duecanali 1604 17 4 IN 442 MM 14 7 IN 373 MM 14 0 IN 357 MM 14 4 IN 365 5 MM ALC 3202 D or AN 2 Channel ALC 404 D or AN ALC 1...

Page 9: ...PLUS CALLBACK PUSHBUTTON 4 SOFT RESET PUSHBUTTON 5 HARD RESET PUSHBUTTON 6 SELF CHECK PUSHBUTTON 7 CH1 CH2 ATTENUATORS CH3 CH4 ALC 404D ALC 1604D 9 8 1 2 6 3 7 4 5 SINGLE ENDED FLIPPED VIEW FLIPPED VI...

Page 10: ...8 A 70V lo Z 35Hz HPF Off 100V hi Z 70Hz HPF On 1 2 3 4 5 6 7 8 F 70V lo Z 35Hz HPF Off 100V hi Z 70Hz HPF On 1 2 3 4 5 6 7 8 D 70V lo Z 35Hz HPF Off 100V hi Z 70Hz HPF On 1 2 3 4 5 6 7 8 B 70V lo Z 3...

Page 11: ...04 models only ALC3202 does not need a dip switch setting for 2 operation Remote On Off Ch 2 Ch 1 common Alarm GPO ALARM CONNECTOR 1 2 3 4 5 6 7 8 Color code TIA EIA 568 B Pin ORANGE WHITE 1 ORANGE 2...

Page 12: ...RED SOLID ON Channel fault1 1 Red LED lights on in case of any kind of channel fault that prevents the normal channel operating Color Name Operating mode Standby Power On GREEN POWER ON SOLID ON ORAN...

Page 13: ...rk with Powersoft to determine the appropriate Service Center to which the ALCs must be shipped and the product s warranty status Biamp will also provide RMA numbers for each unit Do not contact Power...

Page 14: ...mini Drive Beaverton OR 97008 W www biamp com ALC_InstallGuide v 10MAY2022 CONTACT US Email support biamp com Web support biamp com Warranty biamp com legal warranty information Compliance compliance...

Reviews: