7. 

Setup mode 

 

To change the number of DSP levels or listen to the demonstration modes, it is necessary 
to put the module into the setup mode.  
 
To do this, ensure the module is switched off.  Press and hold the DSP level button. Turn 
on the module and a 2 tone beep will be heard indicating that the module is in the set up 
mode.   
 
Releasing the button after the first 2 tone beep will enter demonstration mode 1. 
 
Releasing after the second 2 tone beep will enter demonstration mode 2.  
 
Releasing after the third 2 tone beep will set the unit to level 2 in the 4 level mode. 
 
After the fourth beep, keep the button depressed. 4 beeps will indicate 4 level mode and 8 
beeps 8 levels. Release the button to select the desired level mode.  
 
The module will return to normal operation after this.  The colour of the LED will indicate 
the mode of operation. 

 

8. 

Noise reduction levels. 

 

4 or 8 levels of noise reduction are available. The amount 
of noise and tone reduction is shown in the table below.

 

 

Level

(4)

Level

(8)

Tone Reduction

White Noise Reduction

1

4dB

9dB

1

2

5dB

11dB

3

6dB

13dB

2

4

8dB

15dB

5

16dB

17dB

3

6

21dB

20dB

7

25dB

24dB

4

8

65dB

35dB

 

 

Table 2. Tone and noise reduction levels. 
 

The column marked level (4) shows the noise and tone reduction when operating the 
module with 4 levels, and the level (8) column shows it for 8 levels.  
 
With the DSP noise cancelling switched on (green LED), holding down the function button 
will continuously change the DSP level until the desired level is reached.  
 
Release the button. The module will retain this level until it is changed. 
 

Summary of Contents for Noise Away

Page 1: ...Desk Top Noise Away Amplified DSP noise cancelling Speaker User Manual bhi Ltd DSP noise cancellation products for radio and voice communications 1067 105D iss B...

Page 2: ...bhi Ltd reserves the right to revise this publication and to make changes from time to time in the content hereof without obligation of bhi Ltd to notify any person of such revision or changes Table...

Page 3: ...cancelling unit capable of producing up to 2 5Watts RMS audio power The unit requires an audio input signal of between 80 and 500mW level and a DC supply of between 12 and 18 Volts 300mA The unit is...

Page 4: ...y 300mA 5 Speaker Operation Once installed and connected apply power to both the audio source and the speaker Press the power bypass switch located in the speaker front grill When power is applied to...

Page 5: ...elease the button to select the desired level mode The module will return to normal operation after this The colour of the LED will indicate the mode of operation 8 Noise reduction levels 4 or 8 level...

Page 6: ...on for 1 5 seconds then off for 1 5 seconds It will then move to the next level and repeat the process This mode is particularly effective at demonstrating the different DSP levels A lternatively pas...

Page 7: ...aker Check that the power connector on your power supply is suitable for the power socket on the speaker 2 1mm centre positive Check that you have switched your radio communication equipment on and th...

Page 8: ...n questions otherwise most queries can be resolved over the telephone If not we will arrange with you to have your unit sent back to us for analysis repair or replacement if within 12 months from date...

Page 9: ...at the circuit board is accessible 4 Connect your radio to the speaker connect the power to the speaker and switch the radio on With the speaker in bypass mode power off turn the radio volume to your...

Page 10: ...Page 10 bhi Ltd PO Box 318 Burgess Hill West Sussex RH15 9NR England Telephone 44 0 845 217 9926 Fax 44 0 845 217 9936 Email sales bhi ltd com Web www bhi ltd com 1072 105D iss B...

Reviews: