GENERAL DESCRIPTION 

This unit is designed to not-destructively measure the thickness of non-magnetic coatings (including 
paint, enamel, plastic, epoxy, etc) on steel or iron. 

OPERATION INSTRUCTION 

To Turn on the Unit 
Press and hold down the TEST button for about 2 seconds to turn on the unit. The red LED flashes 
indicating that the unit is in Stand-by mode. 

Normal Operation 

When the unit is in Stand-by state, hold the unit far away from metal and press the TEST button 
briefly to enter Normal Operation mode. Place the unit with the front firmly and in a right angle against 
the coated surface to be measured. If the coating thickness is less than about 1mm, the green LED 
will light up. If the coating thickness is between approximately 1mm and 1.8mm, the yellow LED will 
light up. If the coating thickness is more than about 1.8mm, the red LED will light up. To return to the 
Stand-by state, press the TEST button. If the red LED lights the unit is in normal operation mode. 

Reference Operation 

When the unit is in normal operation mode, place the unit with the front firmly and in a right angle 
against a reference surface whose's coating thickness is less than about 1.8 mm. The thickness of 
the coatings on this surface acts as a reference for further measurement. Press the TEST button 
again to enter reference operation mode, now the red LED and the green LED flash alternately. When 
the unit is removed from the reference surface, the red LED and the yellow LED flash alternately. 
Then press the unit to the target surface which you want to compare with the reference surface. If the 
coating thickness of the target surface is different to the reference surface, the red LED and the 
yellow LED will flash alternately. If the coating thickness of the target surface is the same as that of 
the reference surface, the red LED and the green LED will flash alternately. 

To Return to the Stand-by Mode 

In every operation mode, pressing the TEST button causes the unit return to Stand-by Mode. 

Automatic Power-off 

If the unit has not been operated for about 20 seconds, it will go into Sleep mode automatically. 
In any mode, you can press and hold down the TEST button for more than about 3 seconds to turn off 
the unit manually.

SPECIFICATION

Operating Environment: 0°C – 40°C relative humidity: < 80% 
Storage Environment: -10°C – 60°C relative humidity:< 80% 
Low Battery Indication: All LED flash 
Thickness Detection: 1.8mm 
Tolerance: 0.3mm 
Current Consumption: about 6mA 
Battery: 1x 3V, CR2032, or equivalent 
Dimensions: 68X40X16mm 
Weight: about 30g (including battery) 

DISPOSAL 

Dear Customer, 
If you at some point intend to dispose of 
this article, then please keep in mind that 
many of its components consist of 
valuable materials, which can be 
recycled. Please do not discharge it in 
the garbage bin, but check with your 
local council for recycling facilities in your 
area

Summary of Contents for 63535

Page 1: ...er Front fest und in einem rechten Winkel gegen eine Referenz Oberfläche Schichtdicke 1 8 mm Die Dicke der Beschichtungen auf dieser Referenz Oberfläche dient als Bezug für weitere Messungen Drücken Sie die TEST Taste erneut um in den Referenz Betrieb zu wechseln jetzt blinken rote und grüne LED abwechselnd Nehmen Sie das Gerät von der Referenz Oberfläche rote und gelbe LED blinken abwechselnd Drü...

Page 2: ... thickness is less than about 1 8 mm The thickness of the coatings on this surface acts as a reference for further measurement Press the TEST button again to enter reference operation mode now the red LED and the green LED flash alternately When the unit is removed from the reference surface the red LED and the yellow LED flash alternately Then press the unit to the target surface which you want t...

Page 3: ...e nuevo para entrar en modo de Funcionamiento de Referencia ahora el LED rojo y el verde se encenderán alternativamente Cuando la unidad se quite de la superficie de referencia el LED rojo y el amarillo se encenderán alternativamente Luego presione sobre la superficie que se quiere comparar con la de referencia Si el espesor del recubrimiento de esta es diferente al de la superficie de referencia ...

Page 4: ...ollowing designated product Nous déclarons sous propre responsabilité que ce produit Declaramos bajo nuestra sola responsabilidad que este producto folgenden einschlägigen Bestimmungen entspricht complies with the requirements of the est en conformité avec les réglementations ci dessous esta conforme a las normas Angewandte Normen Norme appliquée Normas aplicadas ppa Frank Schottke Prokurist BGS t...

Reviews: