background image

of improper, incorrect or unreasonable use.

GENERAL SAFETY

Thank you for choosing this product. The Firm is 

confident that its performance will meet your ope-

rating needs.

This product meets recognized technical standards 

and complies with safety provisions when installed 

correctly by qualified, expert personnel (professional 

installer).

If installed and used correctly, the automated system 

will meet operating safety standards. Nonetheless, 

it is advisable to observe certain rules of behaviour 

so that accidental problems can be avoided:

- Keep adults, children and property out of range of

the automated system, especially while it is moving.

- Do not allow children to play or stand within range 

of the automated system.

- This automated system is not meant for use by

children or by people with impaired mental, phy-

sical or sensory capacities, or people who do not

have suitable knowledge, unless a person who is

responsible for their safety provides them with

necessary supervision or instructions on how to

use the device.

- Children must be supervised to ensure they do not 

play with the device. Do not allow children to play

with the fixed controls. Keep remote controls out

of reach of children.

- Do not work near hinges or moving mechanical parts.

- Do not hinder the leaf’s movement and do not

attempt to open the door manually unless the ac-

tuator has been released with the relevant release

knob.

- Keep out of range of the motorized door or gate

while they are moving.

- Keep remote controls or other control devices out

of reach of children in order to avoid the automated 

system being operated inadvertently.

- The manual release’s activation could result in un-

controlled door movements if there are mechanical 

faults or loss of balance.

- When using roller shutter openers: keep an eye

on the roller shutter while it is moving and keep

people away until it has closed completely. Exercise

care when activating the release, if such a device

is fitted, as an open shutter could drop quickly in

the event of wear or breakage.

- The breakage or wear of any mechanical parts of

the door (operated part), such as cables, springs,

supports, hinges, guides…, may generate a hazard. 

Have the system checked by qualified, expert per-

sonnel (professional installer) at regular intervals

according to the instructions issued by the installer 

or manufacturer of the door.

- When cleaning the outside, always cut off mains

power.

- Keep the photocells’ optics and illuminating in-

dicator devices clean. Check that no branches or

shrubs interfere with the safety devices.

- Do not use the automated system if it is in need of

repair. In the event the automated system breaks

down or malfunctions, cut off mains power to the

system; do not attempt to repair or perform any

other work to rectify the fault yourself and instead

call in qualified, expert personnel (professional

installer) to perform the necessary repairs or main-

tenance. To allow access, activate the emergency

release (where fitted).

- If any part of the automated system requires direct 

work of any kind that is not contemplated herein,

employ the services of qualified, expert personnel 

(professional installer).

- At least once a year, have the automated system, and

especially all safety devices, checked by qualified, 

expert personnel (professional installer) to make

sure that it is undamaged and working properly.

- A record must be made of any installation, main-

tenance and repair work and the relevant docu-

mentation kept and made available to the user on

request.

- Failure to comply with the above may result in

hazardous situations.

SCRAPPING

   

Materials must be disposed of in accordance 

with the regulations in force. Do not throw 

away your discarded equipment or used bat-

teries with household waste. You are respon-

sible for taking all your waste electrical and 

electronic equipment to a suitable recycling 

centre.

Anything that is not explicitly provided for in the 

user guide is not allowed. The operator’s proper 

operation can only be guaranteed if the instruc-

tions given herein are complied with. The Firm 

shall not be answerable for damage caused by 

failure to comply with the instructions featured 

herein.

While we will not alter the product’s essential 

features, the Firm reserves the right, at any time, 

to make those changes deemed opportune to 

improve the product from a technical, design or 

commercial point of view, and will not be required 

to update this publication accordingly.

AVVERTENZE PER L’UTILIZZATORE D811767_05

58 -

 VIRgO

D811415_09

Summary of Contents for VIRGO

Page 1: ...E AUTOMATIZACIONES A BRAZO PARA PORTONES CON BATIENTE AUTOMATIZAÇÕES DE BRAÇO PARA PORTÕES DE BATENTE Attenzione Leggere attentamente le Avvertenze all interno Caution Read Warnings inside carefully Attention Veuillez lire attentivement les Avertissements qui se trouvent à l intérieur Achtung Bitte lesen Sie aufmerksam die Hinweise im Inneren Atención Leer atentamente las Advertencias en el interi...

Page 2: ...Fig 1 Fig 3 Fig 2 Fig 5 Fig 6 SX 300 MIN 30 123 180 215 635 230 Fig 4 SX 300 MIN 135 123 63 63 335 120 90 390 230 120 390 230 120 90 Max 210 335 2 VIRGO D811415_09 ...

Page 3: ...Fig 11 Fig 8 Fig 10 Fig 9 Fig 7 S S S ITALIANO ENGLISH FRANÇAIS DEUTSCH ESPAÑOL PORTUGUÊS VIRGO 3 D811415_09 ...

Page 4: ...Fig 12 A C VIRGO BAT SBS 4 VIRGO D811415_09 ...

Page 5: ...Fig 15 Fig 16 Fig 17 LINX JP1 ITALIANO ENGLISH FRANÇAIS DEUTSCH ESPAÑOL PORTUGUÊS VIRGO 5 D811415_09 ...

Page 6: ...Fig 4 Fig 18 Fig 19 LINX UNIDA UNIFLAT 8888 S 1 3 2 Conector programador palmar 6 VIRGO D811415_09 ...

Page 7: ...s place at the main menu level programming is exited and the display switched off The modifications made are only confirmed if the OK key is subsequently pressed END END Message Wait enter value or function OK TCA ON OFF oFF OK PRG OK 3 step ON OFF off OK PRG OK ibl open ON OFF off OK PRG OK fast cls ON OFF off OK PRG OK Fotoc open ON OFF off OK PRG OK TEST PHOT ON OFF off OK PRG OK SCA 2ch ON OFF...

Page 8: ...OK OK ERASE 64 Press P1 pushbutton on radio control device Press the required T key on radio control device see Fig B3 Release P1 on radio control device ADD 2ch hidden button release desired button 01 OK 01 t1 COD RX OK 1A9C OK 22FD OK 01 OK RADIO MENU ADD Allows you to add one key of a radio control device to the receiver memory after storage it displays a message showing the receiver number in ...

Page 9: ...led at a height of at least 1 5 m and in a place where they cannot be reached by the public Apply at least one warning light flashing light in a visible position and also attach a Warning sign to the structure Attach a label near the operating device in a permanent fashion with informa tion on how to operate the automated system s manual release Make sure that during operation mechanical risks are...

Page 10: ...IRGO BAT Kit check that the safety devices are connected correctly 4 OPERATOR INSTALLATION 4 1 Preliminary checks Check that The gate structure is sufficiently sturdy and rigid The fixing position must be worked out according to the leaf structu re In any case the manoeuvring arm must push against a reinforced leaf point The leaves can be moved manually along their entire stroke If the gate has no...

Page 11: ...t by means of the incor porated programmer refer to Fig A and B and to the paragraph on Configuration 10 CONFIGURATION ThedisplayprogrammerisusedtosetalltheLINXcontrolpanelfunctions The programmer is provided with three pushbuttons for menu scrolling and function parameter configuration menu scrolling value increment key menu scrolling value reduction key OKEnter confirm key The simultaneous press...

Page 12: ...e via radio REPLAY CLONI 1 First press the hidden key P1 and then the normal key T1 T2 T3 or T4 of a transmitter already memorised in standard mode by means of the radio menu 2 Within 10s press the hidden key P1 and the normal key T1 T2 T3 or T4 of a transmitter to be memorised The receiver exits the programming mode after 10s other new transmitters can be entered before the end of this time This ...

Page 13: ...r cloning operations thanks to an exclusive system Cloning a transmitter means creating a transmitter which can be au tomatically included within the list of the transmitters memorised in the receiver either as an addition or as a replacement of a particular transmitter Cloning by replacement is used to create a new transmitter which takes the place of the one previously memorised in the receiver ...

Page 14: ...all safety devices limit mi croswitches photocells sensitive edges etc Checkthatthethrust anti squash forceoftheleafiswithinthelimits set by current regulations Check the manual opening command Check the opening and closing operations with the control devices in use Check the standard and customised electronic functioning logic 21 AUTOMATION OPERATION Since the automation can be remote controlled ...

Page 15: ...ficare che ciò non possa causare una situazione pericolosa USER S MANUAL 2 SAFETY ATTENTION The VIRGO model controller is not equipped with mechanical torque adjustment It is compulsory to use a control panel of the same manufacturer in compliance with the basic safety requirementsofdirectives2006 95 CEE 2004 108 CEE 2006 42 CEE equipped with appropriate elec tric adjusment of the torque 3 EMERGEN...

Page 16: ...parte guidata quali ad esempio cavi molle sup porti cardini guide potrebbegenerarepericoli Far controllareperiodicamentel impiantodapersonale qualificato ed esperto installatore professionale secondo quanto indicato dall installatore o dal costruttore della porta Per ogni operazione di pulizia esterna togliere l alimentazione di rete Tenerepuliteleottichedellefotocelluleedidispo sitividisegnalazio...

Page 17: ...s guides maygenerateahazard Have the system checked by qualified expert per sonnel professional installer at regular intervals accordingtotheinstructionsissuedbytheinstaller or manufacturer of the door When cleaning the outside always cut off mains power Keep the photocells optics and illuminating in dicator devices clean Check that no branches or shrubs interfere with the safety devices Do not us...

Page 18: ...n 12 BENELUX BFT BENELUX SA 1400 Nivelles www bftbenelux be POLAND BFT POLSKA SP Z O O 05 091 ZąBKI www bft pl CROATIA BFT ADRIA D O O 51218 Drazice Rijeka www bft hr PORTUGAL BFT SA COMERCIO DE AUTOMATISMOS E MATERIAL DE SEGURANCIA 3020 305 Coimbra www bftportugal com CZECH REPUBLIC BFT CZ S R O Praha www bft it TURKEY BFT OTOMATIK KAPI SISTEMELERI SANAY VE Istanbul www bftotomasyon com tr RUSSIA...

Reviews: