background image

Thank you for buying this product. Our Company is sure that you will be 

more than satisfied with the performance of the product. This product is 

supplied with a “WARNINGS” leaflet and an “INSTRUCTION MANUAL”. 

These should both be read carefully as they provide important informa-

tion about safety, installation, operation and maintenance. This product 

complies with recognised technical standards and safety regulations. We 

declare that this product is in conformity with the following European Direc-

tives: 89/336/CEE, 73/23/EEC, 98/37/EEC and subsequent amendments.

1) GENERAL OUTLINE

Compact electromechanical barrier suitable for limiting private areas, 

parkings, access areas for vehicles only. Available for passageways 

from 3 to 6 metres. Adjustable electromechanical limit devices ensuring 

a correct stop position for the boom. In case of intensive use, a thermal 

sensor activates the cooling fan.

The emergency release device for manual manoeuvre is controlled by a 

personalised key lock.

The actuator is always supplied for left-hand side fitting. However, when 

necessary, the opening direction can be reversed by means of simple 

operations.

The CBO mod. foundation base (on request) makes barrier installation 

easier.

Appropriate fittings make it easy to install accessories without needing 

to drill any holes.

The LEO-MV-D control panel is supplied by the manufacturer with standard 

setting. Any alteration must be set by means of the incorporated display 

programmer or by means of Universal palmtop programmer. The Control 

unit completely supports the EELINK protocol, including the programmer 

self-supply from the control unit.   

Its main characteristics are: 

-  Closing / opening limit-switch inputs

-  Separate inputs for safety devices

-  Clock input

-  Serial protocol connection input

-  Incorporated radio receiver

The board is provided with a terminal board which can be pulled out for 

easier maintenance or replacement. The board is supplied with a series 

of pre-wired jumpers to facilitate the installer’s work.

The jumpers relate to the following terminals: 21-23, 21-24 and 21-30. If the 

above-mentioned terminals are in use,  remove their respective jumpers.

2) GENERAL SAFETY

WARNING! An incorrect installation or improper use of the product 

can cause damage to persons, animals or things.

•   The “Warnings” leaflet and “Instruction booklet” supplied with this 

product should be read carefully as they provide important information 

about safety, installation, use and maintenance.

•   Scrap packing materials (plastic, cardboard, polystyrene etc) according 

to the provisions set out by current standards. Keep nylon or polystyrene 

bags out of children’s reach.

•   Keep the instructions together with the technical brochure for future 

reference.

•   This product was exclusively designed and manufactured for the use 

specified in the present documentation. Any other use not specified 

in this documentation could damage the product and be dangerous.

•   The Company declines all responsibility for any consequences resulting 

from improper use of the product, or use which is different from that 

expected and specified in the present documentation.

•   Do not install the product in explosive atmosphere.

•   The construction components of this product must comply with the 

following European Directives: 89/336/CEE, 73/23/EEC, 98/37/EEC 

and subsequent amendments. As for all non-EEC countries, the above-

mentioned standards as well as the current national standards should 

be respected in order to achieve a good safety level.

•   The Company declines all responsibility for any consequences result-

ing from failure to observe Good Technical Practice when constructing 

closing structures (door, gates etc.), as well as from any deformation 

which might occur during use.

•   The installation must comply with the provisions set out by the follow-

ing European Directives: 89/336/CEE, 73/23/EEC, 98/37/EEC and 

subsequent amendments.

•   Disconnect the electrical power supply before carrying out any work 

on the installation. Also disconnect any buffer batteries, if fitted.

•   Fit an omnipolar or magnetothermal switch on the mains power supply, 

having a contact opening distance equal to or greater than 3,5 mm.

•   Check that a differential switch with a 0.03A threshold is fitted just 

before the power supply mains.

•   Check that earthing is carried out correctly: connect all metal parts for 

closure (doors, gates etc.) and all system components provided with 

an earth terminal.

•   Fit all the safety devices (photocells, electric edges etc.) which are 

needed to protect the area from any danger caused by squashing, 

conveying and shearing, according to and in compliance with the ap-

plicable directives and technical standards.

•   Position at least one luminous signal indication device (blinker) where 

it can be easily seen, and fix a Warning sign to the structure.

•   The Company declines all responsibility with respect to the automation 

safety and correct operation when other manufacturers’ components 

are used.

•   Only use original parts for any maintenance or repair operation.

•   Do not modify the automation components, unless explicitly authorised 

by the company.

•   Instruct the product user about the control systems provided and the 

manual opening operation in case of emergency.

•   Do not allow persons or children to remain in the automation operation 

area.

•   Keep radio control or other control devices out of children’s reach, in 

order to avoid unintentional automation activation.

•   The user must avoid any attempt to carry out work or repair on the 

automation system, and always request the assistance of qualified 

personnel.

•   Anything which is not expressly provided for in the present instructions, 

is not allowed.

•   Installation must be carried out using the safety devices and controls 

prescribed by the EN 12978 Standard. 

3) TECHNICAL SPECIFICATIONS

MOOVI 30S

Power supply: ..........................................................220-230V 50/60Hz(*)

Absorbed power: ............................................................................300W

Motor: .........................................................................2800 min

-1

 2 poles

Capacitor: ..........................25µF 450V (220-230V): 100µF 250V (110V)

Absorption: .......................................................................... 0.8 A - 1.6 A

Insulation class: .....................................................................................F

Ventilation intervention temperature: .............................110 °C (winding)

Circuit-breaking intervention temperature: ........... 130 °C (self-resetting)

Reduction gear lubrication: .........................................Permanent grease

Max torque:.....................................................................................72Nm

Minimum opening time: ..................................................................  1.5 s

Boom (aluminium) length:.......................................................... 3m max.

Impact reaction: ............................. Obstacle detection device (Encoder)

Limit devices: .................................Electric, incorporated and adjustable

Manual manoeuvre: .....................................................Quick key release

Type of use: ...................................................................... semi intensive

Working temperature: .....................................................-10°C to +55 C°

Degree of protection: ........................................................................IP24

Operator weight (without boom): ................................... 356N (~35.6 kg)

Dimensions: ..............................................................................See fig. 1

(*) Special supply voltages available on request.

MOOVI 30 RMM - MOOVI 60 RMM

Power supply: ............................................................. 220-230V 50/60Hz

Absorbed power: ............................................................................300W

Motor: ........................................................................1400 min

-1

, 4 poles

Capacitor: ...............................8µF 450V (220-230V):32µF 250V (110V)

Absorption: ............................................................................ 0.8 A:1.6 A

Insulation class: .....................................................................................F

Ventilation intervention temperature: ..............................110°C (winding)

Circuit-breaker intervention temperature: .............. 130°C (self-resetting)

Reduction gear lubrication: .........................................Permanent grease

Max torque:...................................MOOVI-30 85Nm: MOOVI-60 250Nm

Opening time: ........................................... MOOVI-30 4s : MOOVI-60 8s

(Aluminium) bar length:  ..................................MOOVI-30 3m max: MOOVI-60 6m max

Max 

Impact reaction: ...................... Obstacle detection device (Encoder)

Limiting devices: ............................Electric, incorporated and adjustable

Manual manoeuvre: .....................................................Quick key release

Working temperature: .......................................................-10°C ÷ +55°C

Degree of protection: ........................................................................IP24

Actuator weight (without bar): ........................................ 356N (~35.6 kg)

Dimensions: ...............................................................................See fig.1

(*) Special power voltages available on request.

4) FOUNDATION PLATE (Fig.2)

-   Prepare a foundation hole suitable for the particular kind of ground.

-   Layout several raceways for the electric cables to pass through.

-   Position the screws supplied with the CBO mod. base into the 4 fixing 

holes with the thread facing upwards. Weld the 4 screw heads to the 

base and protect the welds with rust preventer. Position the base so 

INSTALLATION MANUAL

ENGLISH

16

 - MOOVI 30S-30RMM-60RMM  Ver. 01

D81

1998_01

All manuals and user guides at all-guides.com

Summary of Contents for MOOVI 30-60 RMM

Page 1: ... 36015 Schio VI Tel naz 0445 696511 Tel int 39 0445 696533 Fax 0445 696522 Internet www bft it E mail sales bft it ELECTROMECHANICAL CONTROL DEVICE FOR VEHICULAR BARRIERS INSTALLATION AND USER S MANUAL 8 027908 4 3 9 3 6 9 All manuals and user guides at all guides com ...

Page 2: ...the operator manoeuvring area An appropriate pedestrian passageway must be provided for 2 EMERGENCY RELEASE Fig 1 The emergency release allows the bar to be manoeuvred manually It is activated from the outside of the box by inserting the personalised key into the lock placed under the bar and rotating it anticlockwise by 180 WARNING When an actuator without bar needs to be released ensure that the...

Page 3: ...6 CEE 73 23 EEC 98 37 EEC and subsequent amendments Disconnect the electrical power supply before carrying out any work on the installation Also disconnect any buffer batteries if fitted Fit an omnipolar or magnetothermal switch on the mains power supply having a contact opening distance equal to or greater than 3 5 mm Check that a differential switch with a 0 03A threshold is fitted just before t...

Page 4: ... ref A points A B C The ideal securing point for correct balancing of the boom must be chosen according to the barrier type and to the length of the boom and accessories installed Tab 1 of Fig 22 shows the weight expressed in kgs by linear meter kg m for each accessory When the supporting leg Moovi GA AQ AT GAMA AQ is used it is neces sary to calculate the arbitrary weight in Kg m using the follow...

Page 5: ...PARAMETERS submenu then scroll the display screenfuls us ing the up down arrows and set the numerical values of the parameters listed below For the function logics refer to the LOGIC submenu Inthecasewhereprogrammingiscarriedoutbymeansoftheincorporated programmer refer to Fig A and B and to the configuration paragraph 11 Configuration The display programmer is used to set all the LEO MV D control ...

Page 6: ...1 and then the normal key T1 T2 T3 or T4 of a transmitter already memorised in standard mode by means of the radio menu 2 Within 10s press the hidden key P1 and the normal key T1 T2 T3 or T4 of a transmitter to be memorised The receiver exits the programming mode after 10s other new transmitters can be entered before the end of this time This mode does not require access to the control panel OFF T...

Page 7: ...tofrequentlycheckthatallsafetydevicesareperfectlyefficient WARNING In case of any malfunction in the safety devices take imme diate action and require the assistance of a specialised technician It is recommended to keep children at a safe distance from the automa tion field of action 17 CONTROL The automation system is used to obtain motorised access control There are different types of control ma...

Page 8: ...60 RMM MOOVI 30S 30RMM 60RMM Ver 01 21 D811998_01 All manuals and user guides at all guides com ...

Page 9: ...22 MOOVI 30S 30RMM 60RMM Ver 01 D811998_01 All manuals and user guides at all guides com ...

Page 10: ... 600 400 500 20 350 400 100 cm 32 cm 22 cm 835 mm 3m Moovi 30S RMM 6m Moovi 60 RMM Fig 4 Fig 3 1 2 6 3 SX DX 80Nm 4 5 38mm 70mm MOOVI 30S 30RMM 60RMM Ver 01 55 D811998_01 All manuals and user guides at all guides com ...

Page 11: ...Fig 6 Fig 5 Fig 7 Fig 8 56 MOOVI 30S 30RMM 60RMM Ver 01 D811998_01 All manuals and user guides at all guides com ...

Page 12: ...Fig 10 Fig 9 Fig 11 SWC SWO SWC SWO MOOVI 30S 30RMM 60RMM Ver 01 57 D811998_01 All manuals and user guides at all guides com ...

Page 13: ...Fig 12 Fig 13 2 G C 58 MOOVI 30S 30RMM 60RMM Ver 01 D811998_01 All manuals and user guides at all guides com ...

Page 14: ...100 195 237 Fig 14 Fig 15 Fig 16 MOOVI 30S 30RMM 60RMM Ver 01 59 D811998_01 All manuals and user guides at all guides com ...

Page 15: ...17 60 MOOVI 30S 30RMM 60RMM Ver 01 D811998_01 All manuals and user guides at all guides com ...

Page 16: ...18 18 MOOVI 30S 30RMM 60RMM Ver 01 61 D811998_01 All manuals and user guides at all guides com ...

Page 17: ... FLASHING LIGHT MONTAGE DU CLIGNOTANT MONTAGE DER BLINK LEUCHTE MONTAJE DEL INDICADOR PARPADEANTE MONTAGEM DA LÂMPADA CINTILANTE 25 3 9 Per l installazione del lampeggiante fare riferimento ai manuali del lampeggiante See the flashing light s manual for instructions on installing the flashing light Pour monter le clignotant consultez le manuel du clignotant Bitte nehmen Sie für die Installation de...

Page 18: ...a 2 PCA N PCA N PCA N PCA N KIT LIGHT LIGHT LIGHT LIGHT LIGHT LIGHT LIGHT GA GAMA AQ AT GA GAMA GA GAMA GA GAMA GA GAMA GA GAMA GA GAMA GA GAMA GA GAMA GA GAMA GA GAMA BIR BIR BIR BIR BIR BIR BIR MOOVI 60 RMM A MIN L 6 m 3 2 m 3 2 m 3 3 m 3 7 m 3 8 m 4 m 4 2 m 4 3 m 4 5 m 4 8 m 3 4 m 3 4 m 3 6 m 4 1 m 4 2 m 4 4 m 4 6 m 4 7 m 5 m MAX L 6 m 3 5 m 3 6 m 3 7 m 4 2 m 4 3 m 4 5 m 4 7 m 4 8 m 5 m 5 m 3 8...

Page 19: ... bftbenelux be POLAND BFT POLSKA SP Z O O 05 091 ZąBKI www bft pl CROATIA BFT ADRIA D O O 51218 Drazice Rijeka www bft hr PORTUGAL BFT SA COMERCIO DE AUTOMATISMOS E MATERIAL DE SEGURANCIA 3020 305 Coimbra www bftportugal com CZECH REPUBLIC BFT CZ S R O Praha www bft it TURKEY BFT OTOMATIK KAPI SISTEMELERI SANAY VE Istanbul www bftotomasyon com tr RUSSIA BFT RUSSIA 111020 Moscow www bftrus ru AUSTR...

Reviews: