background image

B2. TECHNICAL DATA

B3. INSTALLATION ON COUNTERWEIGHTS-BALANCED DOORS

Main power supply
Motor power supply
Lifting power 
Motor thrust 
Stand-by absorption 
Door dimensions 
Door height
Rail length 

700 N

100 W

8m² max

230V 50Hz

24Vdc

1100 N

150 W

4 W

12m²max

2,4m max

3m

LIBRA

LIBRA PLUS

To use this garage door opener on a counterweghts-balanced door, you need to install the 
adapter arm ARC (buyable as optional).

Before mounting the rail, please see following instructions:
-Take the trolley out of the rail
-remove the four screws on the trolley and open it
-replace the straight bracket with the “boomerang” bracket coming with ARC adapter
-close the trolley and fasten the screws
-put the trolley back into the rail and go on

Please, follow the instructions of ARC adapter to fix it to the door.