![BFT ECOSOL Installation Manual Download Page 16](http://html1.mh-extra.com/html/bft/ecosol/ecosol_installation-manual_2746514016.webp)
When adding batteries...
●
Install (4) new batteries
– Never mix used and new
batteries
●
Make sure they have the same rating
– Batteries may
have the same physical size but have different
characteristics (volts and ampere-hours)
●
Equalize the charge
– all 4 batteries must be within 0.7
volts of each other. An easy way of accomplishing this is by
fully charging them individually before installing.
●
Connect to ECOSOL
- The primary pair of batteries must
be connected to
JP15(-)
and
JP16(+)
while the secondary
pair must be connected to
JP23(+)
and
JP18(-)
.
●
Dipswitch 1
on the ECOSOL board
MUST be turned on
when secondary pair of batteries are connected
The ECOSOL /Libra is shipped with the batteries leads pre-installed.
The negative (black) lead is not connected to prevent discharge
before installation. To power up the system, connect the black lead to
the negative battery terminal
The ECOSOL/Libra enclosure can hold up to (2) pairs (4
total) batteries for greater energy storage capacity. The
battery brackets must be removed and the batteries
must be rotated longways in order to fit them inside the
enclosure.
PRIMARY PAIR
SECONDARY PAIR
WARNING
POWER UP
ADDING MORE BATTERIES
INSTALLING THE BATTERIES
16
www.BFTGateOpeners.com | (800) 878-7829