ITALIANO
ENGLISH
DATI TECNICI
DATI ELETTRICI
Alimentazione
220-230V 50/60Hz
Potenza max. assorbita dalla
rete
BOTTICELLI SMART BT A 850: 200W
BOTTICELLI SMART BT A 1250: 250W
Fusibili
vedi Fig. L-S
Alimentazione accessori
24V~ (180mA max)
24Vsafe (180mA max)
Collegamento lampeggiante
24V~ max 25W
Luce cortesia
Lampadina a led di cortesia mod. BFT 24V
2W
Temperatura di funzionamento
-20°C / +60°C
DATI MECCANICI
Forza trazione e spinta
BOTTICELLI SMART BT A 850: 850N
BOTTICELLI SMART BT A 1250: 1250N
Anta max
BOTTICELLI SMART BT A 850 : 13m2
BOTTICELLI SMART BT A 250 : 16m2
Corsa utile
BINARIO L.=2900 corsa utile=2300 mm
BINARIO L.=3500 corsa utile=2900 mm
Velocità massima
BOTTICELLI SMART
BT A 850
Binario a cinghia=
240 mm/s
Binario a catena=
210 mm/s
BOTTICELLI SMART BT
A 1250
Binario a catena=
190 mm/s
Manovre in 24 ore @ MAX+60°C
BOTTICELLI SMART BT A 850: 50
BOTTICELLI SMART BT A 1250: 100
Manovre in 1 ora @ MAX+50°C
10
Installazione ti-
pica sezionale a
20°C
BOTTICELLI SMART BT A 850: mq 6,7
100 manovre con-
secutive
BOTTICELLI SMART BT A 1250: mq 15,7 50 manovre conse-
cutive
Reazione all’urto
Limitatore di coppia integrato su quadro
comando
Finecorsa
Elettronico ad ENCODER
Lubrificazione
Grasso permanente
Grado di protezione
IP20
Peso testamotore
5 kg
Rumorosità
<70dB(A)
Dimensioni
Vedi fig.B
DATI RICEVITORE INCORPORATO
Radioricevente Rolling-Code in-
corporata
Frequenza 433.92 MHz
Codifica
Algoritmo Rolling-Code
N° combinazioni
4 miliardi
N° max radiocomandi memorizzabili 63
INSTALLAZIONE ATTUATORE Fig.A
Predisporre l’arrivo dei collegamenti degli accessori, dei dispositivi di sicurezza
e di comando al gruppo motore tenendo nettamente separati i collegamenti a
tensione di rete dai collegamenti in bassissima tensione di sicurezza (24V). Pro-
cedere al loro collegamento come indicato nello schema elettrico.
I cavi di connessione accessori devono essere protetti da canaletta.
Verifiche preliminari:
• Controllare il bilanciamento della porta.
• Controllare lo scorrimento della porta per tutta la corsa.
• Se la porta non è di nuova installazione, controllare lo stato di usura di tutti i
componenti.
• Sistemare o sostituire le parti difettose o usurate.
• L’affidabilità e la sicurezza dell’automazione è direttamente influenzata dallo
stato della struttura della porta.
• Prima di installare il motore, togliere eventuali funi o catene superflue e disa-
bilitare qualsiasi apparecchiatura non necessaria.
TECHNICAL SPECIFICATIONS
ELECTRICAL DATA
Power supply
220-230V 50/60Hz
Max. power absorbed from mains
BOTTICELLI SMART BT A 850: 200W
BOTTICELLI SMART BT A 1250: 250W
Fuses
see figure L-S
Supply to accessories
24V~ (180mA max)
24Vsafe (180mA max)
Blinker connection
24V~ max 25W
Courtesy light
BFT model courtesy LED lamp 24V
2W
Operating temperature
-20°C / +60°C
MECHANICAL DATA
Pulling and pushing force
BOTTICELLI SMART BT A 850: 850N
BOTTICELLI SMART BT A 1250: 1250N
Leaf max.
BOTTICELLI SMART BT A 850 : 13m2
BOTTICELLI SMART BT A 250 : 16m2
Working stroke
TRACK L.=2900 working stroke=2300 mm
TRACK L.=3500 working stroke=2900 mm
Maximum speed
BOTTICELLI SMART BT
A 850
Belt track= 240
mm/s
Chain track= 210
mm/s
BOTTICELLI SMART BT
A 1250
Chain track= 190
mm/s
Manoeuvres in 24 hours@
MAX+60°C
BOTTICELLI SMART BT A 850: 50
BOTTICELLI SMART BT A 1250: 100
Manoeuvres in 1 hour@ MAX+50°C 10
Typical instal-
lation of sec-
tional doors
at 20°C
BOTTICELLI SMART BT A 850: mq 6,7
100 consecutive ma-
noeuvres
BOTTICELLI SMART BT A 1250: mq 15,7 50 consecutive ma-
noeuvres
Impact reaction
integrated torque limiter on control panel
Limit switch
Electronic with ENCODER
Lubrication
permanent grease
Degree of protection
IP20
Motor head weight
5 kg
Noise level
<70dB(A)
Dimensions
see fig.B
INCORPORATED RECEIVER DATA
Incorporated rolling-code
radio receiver
Frequency 433.92 MHz
Coding
rolling-code algorithm
No. combinations
4 billion
Max no. radio controls to be
memorised
63
ACTUATOR INSTALLATION Fig.A
Arrange for the connections of accessories and safety and control devices to reach
the motor unit, keeping the mains voltage connections clearly separate from the
extra low safety voltage connections (24V).
Proceed to connection following the indications given in the wiring diagram.
The cables for connecting the accessories must be protected by a raceway
Preliminary checks
• Check that the door is balanced.
• Check that the door slides smoothly along its entire travel.
• If the door has not been newly installed, check the wear condition of all its
components.
• Repair or replace faulty or worn parts.
• The automation reliability and safety are directly influenced by the state of
the door structure.
• Before fitting the motor, remove any superfluous ropes or chains and disable
any unnecessary appliances.
54
BOTTICELLI SMART BT A 850-1250
D814089 0AA00_08
Summary of Contents for BOTTICELLI SMART BT A 850-1250
Page 29: ...BOTTICELLI SMART BT A 850 1250 59 D814089 0AA00_08 ...
Page 30: ......