2.6
SPECIFYING THE FLUE SYSTEM & ASSOCIATED COMPONENTS
2.6.1
This product requires a minimum vertical flue length of 150mm (6 inch).
The horizontal length can then be extended up to a maximum of
1600mm, giving a total depth from mounting flange to outer wall of
2000mm. The standard flue kit supplied with the product comprises the
following components :-
1 off
Flue terminal
1 off
Flue terminal guard
1 off
150mm starter pipe
1 off
250mm minimum to 410mm maximum telescopic flue pipe
1 off
90 degree elbow
3 off Pipe clips
This kit comprises the components required to fit the appliance into a studded wall
or a chimney breast with a maximum depth of 880mm (from mounting flange of
combustion chamber to outer face of wall) The main flue pipe section is a
telescopic item which allows for a variation in depth of 160mm minimum to
maximum length (250mm to 410mm). See figure 13 below.
Fig. 13
13
Minimum
Wall
Thickness
Excluding
Flue Terminal
320mm
Flue Terminal Length
200mm
Maximum Wall Thickness
Excluding Flue Terminal
410mm
Flue Terminal
Length 200mm
90 Degree Elbow
150mm
Starter Pipe
90 Degree Elbow
150mm
Starter Pipe
Telescopic Flue Section
Telescopic Flue Section