Function
Code
Name of Function
Applicable Range
Factory
Default
Remarks
Ur
Information on version
Program Version
Ex.
1.0
See page 11
F
Drive frequency range
90:45 to 90Hz(Half-wave)
180:90 to 180Hz(Full-wave)
360:180 to 360Hz (High-frequency)
120:65 to 120Hz(Middle-frequency)
180 See page 14
Sen
Direction of stroke sensor
0: Reverse phase
1: Synchronous phase
2: Automatic setting
0
See page 28
rnt
Remote
0: Panel operation
1: 4-20 mA current control
2: Two-Rate-of-Feed with two external rheostats
0
See page 34
E-
Error code
Error Code of arising error
E-
See page 42
rS
Run/Stop by the Panel mode
0: Running and stopping by RUN/STOP button on the panel
1: Power supply runs the feeder ignoring RUN/STOP
button
1
See page 8
con
Logic of external signal
“P1”, “P2”
0: “P1” and “P2” is open
1: “P1” and “P2” is close
0
See page 29
H
Scaling of the stroke
Scaling coefficient: 1.00 to 5.00
1.00 See page 22
G
Control Gain
Gain Range: 0.01 to 9.00
On the auto-tuning and constant stroke mode,
adjusting gain improves responsibility and
stability of soft start and etc.
1.00
See page 21
See page 24
Fb
Feedback Gain
0: Normal
1: Fine
In the case frequency range “F360” is selected
the feedback gain is set for “Fine”
automatically.
0/1 See page 17
Loc
Key Lock
0: Lock off
1: Lock on
0
See page 24
Function Table
Function Table