Beyond BY-P23B User Manual Download Page 3

 

supply   match   the power requirements of the unit. 

 

It

’s   important   to   ground   the   yellow/green   conductor   to   earth   in   order   

to   avoid   electric shock. 

 

The unit is for indoor use only. Use only in a dry location. 

 

The   unit   must   be   installed   in   a   location   with   adequate   ventilation,   at   

least   50cm   from adjacent surfaces. Be sure that no ventilation slots are 

blocked. 

 

Disconnect main power before replacement or servicing. 

 

 

Make sure there are no flammable materials close to the unit while operating as 

it is fire hazard. 

 

Use safety cable when fixes this unit. DO NOT handle the unit by taking its head 

only, but always by taking its base. 

 

 

Maximum ambient temperature is Ta: 40

. DO NOT operate it where the 

temperature is higher than this Unit surface temperature may reach up to 85

DO NOT touch the housing bare-hand during its operation. Turn off the power 

and allow about 15 minutes for the unit to cool down before replacing or serving. 

 

 

In  the  event  of  serious  operating  problem,  stop  using  the  unit 

immediately.Never  try  to  repair  the  unit  by  yourself.  Repairs  carried  out by 

unskilled  people  can  lead  to  damage  or  malfunction.  Please  contact  the 

nearest  authorized  technical assistance  center.  Always  use  the  same  type 

spare parts. 

 

 

DO NOT touch any wire during operation as high voltage might be causing 

electric shock. 

 

Warning: 

 

 

To prevent or reduce the risk of electrical shock or fire, do not expose the unit to 

rain or moisture. 

 

DO NOT open the unit within five minutes after switching off. 

Summary of Contents for BY-P23B

Page 1: ...7 4in1 Osram 15w beam zoom par User manual Please read the instructions carefully before use ...

Page 2: ...tem and manual any misuse cause of the damages are not included in our guarantee and also can not be responsible for any malfunction problem owing to ignore the manual 1 Safety Instructions Please keep this User Guide for future consultation If you sell the unit to another user be sure that they also receive this instruction booklet Unpack and check carefully there is no transportation damage befo...

Page 3: ...ent temperature is Ta 40 DO NOT operate it where the temperature is higher than this Unit surface temperature may reach up to 85 DO NOT touch the housing bare hand during its operation Turn off the power and allow about 15 minutes for the unit to cool down before replacing or serving In the event of serious operating problem stop using the unit immediately Never try to repair the unit by yourself ...

Page 4: ...erating And make sure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times of the unit s weight Also always use a safety cable that can hold 12 times of the weight of the unit when installing the fixture The equipment must be fixed by professionals And it must be fixed at a place where is out of the touch of people and has no one pass by or u...

Page 5: ... control with a DMX 512 controller connect several lights together dmx in and dmx out 3 pin XLR connectors Pin 1 GND Pin 2 Negative signal Pin 3 Positive signal Display MENU To select the programming functions DOWN To go backward in the selected functions uP To go forward in the selected functions ENTER To confirm the selected functions Set DMX Ad d res s Cod e ...

Page 6: ...ave G255 Green brightness adjustment Press up and down button to set the brightness press Enter button to save B255 Blue brightness adjustment Press up and down button to set the brightness press Enter button to save H255 Blue brightness adjustment Press up and down button to set the brightness press Enter button to save Pr01 Built in program set 01 Press up and down button to choose the program p...

Page 7: ...slow to fast 5 0 255 G dimming slow to fast 6 0 255 B dimming slow to fast 7 0 255 W dimming slow to fast 8 0 255 Rainbow 9 Music mode or Auto Run mode 0 60 Show the effect from CH1 CH8 61 120 Jump change 121 180 Gradual change 181 244 Jump change gradual change strobe 245 255 Music mode 10 Speed 0 255 Fast to slow 11 Zoom speed 0 255 Fast to slow 12 Reset 0 64 No funcation 65 128 Auto run 129 192...

Page 8: ...8 4 SHAPE ...

Page 9: ...rs cables to see if link properly 2 If the DMX LED is on and no response to the channel check the address settings and DMX polarity 3 If you have intermittent DMX signal problems check the pins on connectors or on PCB of the unit or the previous one 4 Try to use another DMX controller 5 Check if the DMX cables run near or run alongside to high voltage cables that may cause damage or interference t...

Page 10: ...frequency depends on the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit s optics Clean with soft cloth using normal glass cleaning fluid Always dry the parts carefully Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days ...