Bewator FH07B Series Installation Instructions Manual Download Page 5

FH07B Series Installation Instructions Issue 3.0 

 

INS00306                      Page 5 of 24 

Introduction 

General Description 

Hazardous Areas 

 

The Phoenix™ 7” FH07B Series Flameproof Camera Housing is certified to the EC (ATEX) 
Directive 94/9/EC for use in hazardous areas. 
 
A hazardous area is defined as an area in which explosive atmospheres are, or may be 
expected to be, present in quantities such as to require special precautions for the 
construction and use of electrical equipment.  An explosive atmosphere consists of a mixture 
of flammable substances with air in the form of gas, vapour, mist or dust in such proportions 
that it can be exploded by excessive temperatures, arcs, sparks or flames. 
 
Equipment is housed in an enclosure into which gas may gain access.  Should this gas be 
ignited within the enclosure, the resulting explosion will not reduce the pressure integrity of 
the enclosure or will not be transmitted to any flammable atmosphere external to the 
enclosure. 
 
Note: This equipment may contain an ignition source even after disconnection. 

 

Customer Orders 

 

The FH07B Series of Flameproof Camera Housings are fitted with a customer (free issue) 
supplied Camera and Lens and supplied with ATEX Equipment Certification by Bewator Ltd., 
at an additional cost.  (Bewator Ltd. Part Number 

FH07-CERT

).  The Camera/Lens and the 

installation MUST be compatible with the certification to the EC (ATEX) Directive 94/9/EC, 
see Page 11.  Bewator Ltd. can supply and fit suitable cameras and lenses on request. 
 
The FH07B Series of housings can be supplied fitted with the following optional accessories: 

FH07W

 

Wiper Unit Kit ~ 230Vac ~ 50/60Hz. 

FH07W/L

 

Wiper Unit Kit ~ 24Vac ~ 50/60Hz. 

FH07W/U

 

Wiper Unit Kit ~ 110Vac ~ 60Hz. 

FH07-RX210

  10 - function Receiver Kit ~ 110-230Vac. 

FH07-RX217

  17 - function Receiver Kit ~ 230Vac. 

FH07-TKIT

 

Tamper Switch Kit. 

To ensure compliance with the certification to the EC ‘ATEX’ Directive 94/9/EC, ANY of 
these optional accessories MUST be pre-ordered and supplied factory fitted by Bewator Ltd. 
 
The maximum combined power dissipation for all of the equipment fitted into the Camera 
Housing MUST not exceed: 

 FH07B-40 

Series 

63W 

 FH07B-30 

Series 

50W 

 
To ensure compliance with the EC (ATEX) Directive 94/9/EC, all orders that are placed for 
Phoenix™ 7” FH07B Series Camera Housings MUST follow Bewator Ltd. Procedure 
20G040, which includes the completion of a Phoenix™ Pre-Compliance Form by the 
customer. 

 

Summary of Contents for FH07B Series

Page 1: ...FH07B Series Phoenix 7 Flameproof Camera Housing INS00306 Page 1 of 24 Installation Instructions Manual INS00306 Issue 3 0...

Page 2: ...stallation 9 After Installation 9 Suggested Tools 10 ORDERING THE FH07B SERIES UNIT 11 Certification Requirements For The Camera Lens 11 INSTALLING THE FH07B SERIES UNIT 12 Removing The Rear Cap Assem...

Page 3: ...s intended Check operating temperatures and where applicable protection against water ingress specifications Please take particular care that the inter connected equipment is fully compatible with eac...

Page 4: ...sure to provide suitable access equipment to ensure the safety of installation or service personnel working on the equipment INSTALL CORRECTLY All persons installing and maintaining this equipment sho...

Page 5: ...Housings are fitted with a customer free issue supplied Camera and Lens and supplied with ATEX Equipment Certification by Bewator Ltd at an additional cost Bewator Ltd Part Number FH07 CERT The Camer...

Page 6: ...ene or gases of an equivalent hazard Also includes Gas Group IIA for atmospheres containing propane or gases of an equivalent hazard Zone 1 Hazardous area zone Where an explosive atmosphere is likely...

Page 7: ...ting screws into the Front Plate Assembly mounting holes MUST NOT exceed 8mm It is recommended that dimensional checks be performed to determine the correct length of the M4 mounting screws The Rear C...

Page 8: ...FH07B Series Installation Instructions Issue 3 0 INS00306 Page 8 of 24 Figure 1 Typical Flameproof Camera Housing Figure 2 Detail Showing Flame Path Zone Locations...

Page 9: ...21 1 x Installation Instructions INS00306 Optional 1 x Optional Accessories Packing Kit comprising Either 1 x Installation Instructions INS00054 complete with D Type Telemetry Module 10 function Recei...

Page 10: ...suggested for the installation of a FH07B Series Flameproof Camera Housing 3mm A F across flats Allen key 5mm A F across flats Allen key 10mm A F across flats Allen key No 1 Posidrive screwdriver Torq...

Page 11: ...9 EC Equipment group II Category 2 the Camera Lens to be fitted into the FH07B Series Camera Housing MUST adhere with the maximum requirements shown in Figures 3 and 4 Cameras and Lenses with equal o...

Page 12: ...iphery of the Rear Cap Assembly Retain for future use See Figure 5 c Screw the 3 off M5 Special Rear Cap Removal Screws into the special screw holes and gradually tighten in sequence to withdraw the R...

Page 13: ...fferent cable specifications may also be used if necessary Any of the supplied stopping plugs 4 off normally fitted may also be used 5 Note Electrical installation methods should comply with current l...

Page 14: ...minal Block Assembly The L wire is connected via the Thermostat which is mounted on the inside of the Rear Cap Assembly 3 The user supplied mains input cable enters the housing through one of the 4 ca...

Page 15: ...through 1 of the 4 cable entries using a suitable cable gland The Earth wire MUST be connected as the primary Earth to the Earth Stud on the inside of the Rear Plate See Figure 7 The Live and Neutral...

Page 16: ...ceiver MUST be connected and tested in accordance with the Installation Instructions INS00054 4 Confirm that the special Earth wire is connected between the Earth Stud on the inside of the Rear Cap As...

Page 17: ...allation Instructions INS00093 4 Note The 17 function Receiver MUST be connected and tested in accordance with the Bewator Ltd Installation Instructions INS00093 Release the 4 plastic clip fasteners f...

Page 18: ...m is resting in the PARK position ii Confirm that the rear wiper shaft coupling is correctly aligned with the wiper drive unit mating half coupling e Locate the Monorail locating spigot into the circu...

Page 19: ...ounted to a bracket a column spacer and a pan and tilt PTZ unit or directly to a suitable structure 3 Two sets of 4 x M6 screw mounting holes equi spaced on a 4 101 6mm p c d pitch circle diameter are...

Page 20: ...nd wear Perform checks to ensure that cables are not fouling on any obstruction Check cables for signs of wear Replace as necessary If fitted the wiper arm and blade should be checked for wear or corr...

Page 21: ...0 C Construction Body Machined aluminium extrusion Front Cap Machined aluminium with toughened glass window Rear Cap Machined aluminium with 4 off M20x15 screw gland cable entry holes normally fitted...

Page 22: ...NS00306 Page 22 of 24 Mechanical Dimensions The physical dimensions for the FH07B Series Phoenix 7 Flameproof Camera Housing are shown below All measurements are given in millimetres Note All specific...

Page 23: ...FH07B Series Installation Instructions Issue 3 0 INS00306 Page 23 of 24 Wiring Diagram Note These circuits are example layouts only Refer to Bewator Ltd for further detail...

Page 24: ...ny Street Newport South Wales United Kingdom NP20 5XW Telephone 44 0 1633 821000 Fax 44 0 1633 850893 Email sales bewator co uk Internet http www bewator co uk Customer Support Tel 44 0 1633 820615 Wh...

Reviews: