CONDENSER CLEANING
Keeping the condenser coil clean is critical to efficient
operation.
1. Unplug unit from power supply.
2.
Rotating fan blade can cause
personal injury.
Unplug unit from power supply
before beginning to clean
condenser
CAUTION
3. Remove two Phillips head screws from the top
corners of the front panel
4. Lift upwards on the front panel to remove
5. To reinstall the front panel line up the keeper screws
behind the panel and firmly pull downwards
6. Reinstall the screws on the top corners
7. Examine condenser surface, if dusty, brush and
vacuum the dust and lint from the surface of the
coil. Brush up and down to avoid damaging the fins.
Use care to not disturb the wires connected to the
controller.
Note: If the coil is greasy, the coil will need to be
cleaned with coil cleaner and that should be left to an
experienced technician.
8. Return grille to unit.
Note: Air filters are not recommended as they restrict
the flow of cooling air.
Remove Screws
Condenser Surface
Push Up and Off