User Manual for MT Refrigerators and Freezers
Beverage-Air
Rev. 07/22
Beverage-Air
11
This is a cord-connected unit, and must be connected to it's own
dedicated
power supply. Beverage Air coolers with HC
refrigerants (R-290/R-600) are designed to operate at specific voltages. Prior to installation, check equipment serial
number and the dataplate on the machine to confirm the voltage and per the dataplate use the correct fuses or HACR
circuit breakers.
Note: Do not connect to GFI / GFCI outlets. Connection to that type of outlet can result in product loss due to
unsafe cabinet temperature when GFI device trips from moisture.
IMPORTANT: ground connection is a protection system for equipment connected to an electrical network.
It is used in electrical installations to avoid current pass-through to use, due to an isolation failure of active
conductors. This cooler must be connected to a physical ground. In case a short circuit occurs, ground
connection reduces the risk of electrical shock.
Power Cord
This 115 volt model is equipped with a polarized power cord
with a grounded 5-15P connection plug. Do not attempt
to eliminate the ground connection or use two-terminal
adapters. Plug must be connected to an adequately-
installed and grounded outlet. If the owner does not
have this type of outlet, it is their responsibility to have
one installed. Please contact a cerified electrician or a
certified technician if you have questions.
If the power cord becomes damaged, it must be replaced
with the identical cord. Using extension cords will void
the warranty.
Follow All National and Local Codes
This Unit Must Be Grounded. Do not use extension cords
and do not disable or by-pass ground prong on electrical
plug.
Initial Start Up
Plug the power cord into the proper power supply.
Connect the plug firmly into the electrical outlet making
sure it is inserted properly.
The cabinet will soon begin to blow warm air out of the
top area, and cool air will flow from the inside blower.
The cabinet temperature has been set at the factory and
should not need adjustment, however if it was changed,
the standard setting for refrigerators is 36.3º F for single
door equipment and 35.4°F for two door equipment.
The freezers will be set to 0°F at the factory, but the
temperature for the freezers cannot be adjusted and must
remain at 0°F.
Cautions
Care must be taken whenever moving or servicing the
unit. The refrigerant is contained in a sealed system, but if
released it may be flammable.
In order to avoid severe electrical shock, do not remove
the third ground connection pin from power cord or use
an adapter.
If the power cord or other electronic components are
damaged, contact the manufacturer or authorized service
technician for repair to avoid injury or electrical shock.
ELECTRICAL
Summary of Contents for MT06
Page 58: ...User Manual for MT Refrigerators and Freezers Beverage Air Rev 07 22 Beverage Air 58 DOOR...
Page 63: ...User Manual for MT Refrigerators and Freezers Beverage Air Rev 07 22 Beverage Air 63 DOOR...
Page 68: ...User Manual for MT Refrigerators and Freezers Beverage Air Rev 07 22 Beverage Air 68 DOOR...
Page 73: ...User Manual for MT Refrigerators and Freezers Beverage Air Rev 07 22 Beverage Air 73 DOOR...
Page 78: ...User Manual for MT Refrigerators and Freezers Beverage Air Rev 07 22 Beverage Air 78 DOOR...