5
Never try to retrieve the device if it falls into water. Disconnect the plug immediately from the mains outlet.
Do not use the device if damage to the device itself or any of its accessories is evident.
Do not subject the device to any impact and do not drop it.
Repairs
WARNING
• Repairs to electrical appliances must only be carried out by qualified persons. Incorrect repairs can
lead to considerable danger for the user. In the event of repairs, please contact our customer service
or an authorized dealer.
• The zip fastener on the Shiatsu massage device must not be opened. It is only fitted for reasons
relating to the manufacturing of the device.
Fire hazard
WARNING
There is a risk of fire if the device is used incorrectly or if it is not used according to these operating
instructions.
For this reason, the massage device must only be operated as follows:
• Never use the device under covers, such as blankets or pillows.
• Never use the device in the vicinity of petrol or other easily flammable materials.
Handling
CAUTION
Switch the device off and disconnect the power supply after every use and before every cleaning.
• Never insert any objects into openings on the device, and never insert anything into the
rotating parts. Make sure that all moving parts can move freely at all times.
• Never sit or stand on the moving parts of the device with all your weight and do not place
objects on the device.
• Keep the device away from high temperatures.
6. Proper use
This device is intended only for the massaging of individual parts of the human body. It cannot replace medical
treatment. Do not use the massage device if any of the following warnings apply to you. Please consult your
doctor if you are unsure whether or not the massage device is suitable for you.
WARNING
Use of the massage device is prohibited in the following cases:
• On animals.
• if you suffer from a medical abnormality or injury in the area to be massaged (e.g. herniated disc,
open wounds),
• Never use the massage device to massage the heart region of persons fitted with a pacemaker.
Always consult a doctor before using the massage device on other parts of the body of a person
fitted with a pacemaker.
• Never use the massage device on swollen, burned, inflamed or damaged skin or body parts.
• The massage device must not be used on lacerated wounds, capillaries, varicose veins, acne, coup-
erose, herpes or other skin diseases.
• The massage device must not be used during pregnancy.
• Do not use the massage device on the face (eyes), on the larynx or on other particularly sensitive
parts of the body.
• Do not use the device for foot massage.
• Never use the device while you are asleep.
• Never use the device after taking medication or consuming alcohol (reduced levels of awareness).
• Not in the car.
You should consult your doctor before using the massage device if:
• you suffer from a serious illness or are recovering from an operation on the upper body,
• you are fitted with a cardiac pacemaker, implant or other aid,
• Thromboses,