Storage
(ON) activated. The "beurer HealthManager" app must also be open on the smartphone.
Bluetooth® on the smartphone and on the pulse oximeter
• Variant 2: The data is automatically transferred to the app after the measurement. “SYNC” flashes on the display.
The device tries to connect to the app for 10 seconds. As soon as a connection is established, "SYNC" stops
flashing. All measurement data in the memory are automatically transferred to the app. The pulse oximeter then
switches off automatically. If Bluetooth®
is
deactivated (OFF), the message OFF is displayed after your
measurement.
To be able to save readings with the correct date, we advise you to connect your PO 60 to your smartphone
before taking your first measurement.
The "beurer HealthManager" app must be activated for the transfer.
There are two ways to sync data with your smartphone. In both variants must
•
Proceed as follows to transfer
the readings to your smartphone
via
Bluetooth® :
Activate
Bluetooth® in the
settings on your smartphone, open the "beurer HealthManager" app and follow the instructions. Select and
connect the PO 60 in the settings menu of the app. A randomly generated six-digit PIN code is displayed on the
pulse oximeter, and at the same time an input field appears on the smartphone in which you must enter this six-
digit PIN code.
• Each time data is transferred, the time and date are synchronized with the smartphone. To all yours
• Variant 1: Hold down the function button on the switched-off pulse oximeter for 5 seconds. “SYNC” flashes on
the display. The device now tries to establish a connection to the app for 10 seconds. Once connected, “SYNC”
will stop flashing. All measurement data in the memory are automatically transferred to the app. The pulse
oximeter then switches off automatically.
The pulse oximeter uses Bluetooth® low energy technology,
0483
- iOS ab 10.0, AndroidTM ab 5.0
- ab Bluetooth® 4.0
ÿ NOT on fingers that are too thin and too small, such as those found in small children (width approx.
< 10 mm, thickness approx. < 5 mm).
physical, sensory or mental abilities or lack of experience and/or lack of knowledge, unless they are
supervised by a person responsible for their safety or have received instructions from them on how to use
the device. Children should be supervised to ensure they do not play with the device. • The display of the
pulse wave and the pulse column do not allow any assessment of the pulse or blood flow
ÿ NOT if you are allergic to rubber products.
ÿ NOT on patients who are restless at the application site (eg tremors).
strength at the measurement location, but only serve to display the current optical signal variation at the
measurement location, but they do not enable reliable pulse diagnostics.
ÿ NOT if the device or the application finger is wet.
ÿ NOT in the vicinity of flammable or explosive gas mixtures.
Finger, hand or body is in motion.
ÿ NOT on small children or infants.
ÿ NOT during an MRI or CT scan.
ÿ NOT during a blood pressure measurement on the arm side with cuff application.
ÿ NOT on fingers with nail polish, dirt or plaster bandages.
ÿ NOT on thick fingers that cannot be easily inserted into the device (fingertip: width approx. > 20 mm,
thickness approx. >15 mm)
ÿ NOT on fingers with anatomical changes, edema, scars or burns.
• Danger of swallowing! Small children could swallow batteries and choke on them. Therefore, keep
batteries out of the reach of small children!
Operating
98 65
%SpO2 PRbpm
Permissible storage and
consequences for humans
SpOÿ 70 –100%, ±2%,
No data transmission
of the measured values
possible
< 90
read no matter how you hold the pulse oximeter.
Use the pulse oximeter
3. Close the battery compartment
cover again.
~90
Hemoglobin (in percent)
Doctor visit recommended
Equipment)
Do not use high-pressure sterilization on the pulse oximeter!
Only use the Beurer PO 60 pulse oximeter on humans to measure arterial oxygen saturation (SpOÿ) of hemoglobin
and heart rate (pulse rate). The pulse oximeter is suitable for use both in the private sphere (at home) and in the medical
field (hospitals, medical facilities).
Your Beurer team
Frequency band 2402 MHz - 2480 MHz,
transmission power max. 2.87 dBm,
2. Pulse rate (value in beats per minute)
• Brightness function: To set your desired display brightness, keep the function button pressed during operation.
Model no.
altitude
The following symbols are used in the instructions for use, on the packaging and on the type label of the device:
You can find the CE declaration of conformity for this product at: www.beurer.com/web/we-landingpages/de/
Keep your fingers, hand and body still
during the measurement.
Cd = battery contains cadmium, Hg
= battery contains mercury
Permissible storage temperature
and humidity
seconds your readings.
The following table for evaluating your measurement results does NOT apply to people with certain pre-existing conditions
(e.g. asthma, cardiac insufficiency, respiratory diseases) and for stays at altitudes of over 1500 meters. If you have any
pre-existing conditions, always consult your doctor to evaluate your readings.
guard are used.
WEEE (Waste Electrical and Electronic
pelter form should be avoided as it could result in erroneous operation. If use of the prescribed type is nevertheless
necessary, this device and the other devices should be observed to ensure that they are working properly.
-40°C to +60°C, ÿ95% relative humidity, 500–1060 hPa ambient pressure
SpOÿ 0 – 100%,
pulse 30 – 250 bpm
Substances.
Activate Bluetooth® on the smartphone and
start the app.
- With each data transfer, the time and date are synchronized with the smartphone.
contraction, erroneous or falsified measurements can occur.
2. Place the two included
your treating doctor. In particular, do not start a new medication on your own and do not make any changes to the type
and/or dosage of an existing medication.
receiving diode
> 90
Arterial oxygen saturation
Degraded area:
3. Appear on the screen after a few
2. Tighten the other end of the lanyard through the loop of
the narrow end.
The table below informs you about the effects of different altitudes on the oxygen saturation value and their consequences
for the human organism. The following table does NOT apply to people with certain pre-existing conditions (e.g. asthma,
heart failure, respiratory diseases, etc.). Symptoms of illness (e.g. hypoxia) can already occur at lower altitudes in persons
with pre-existing conditions.
With kind regards
• Transfer measured values to app plus synchronization of time and date: See 10. “Transfer of measured values via
Bluetooth® low energy technology”.
Expected SpOÿ value (oxygen
saturation) in %
1. Oxygen saturation (value in percent)
• Activate and deactivate Bluetooth® :
Batteries containing harmful substances are not included
• Batteries must not be charged or short-circuited.
Thickness between 5 -15mm.
Subject to errors and changes
• You will find these symbols on batteries containing harmful
substances: Pb = battery contains lead,
Sensor technology for measuring SpOÿ red light (wavelength 660 nm); infrared (wavelength 905 nm); silicon
• Power on function: When the pulse oximeter is turned off, you can turn it on by briefly pressing the
If, during the guarantee period, this product proves to be incomplete or defective in terms of functionality in accordance with
the following provisions, Beurer will carry out a replacement delivery or repair free of charge in accordance with these
guarantee conditions.
Waste electronic devices EC Directive
2500-3000 m
You can attach a lanyard to the device to make it easier to carry the pulse oximeter.
pressure
In the interest of environmental protection, the device must not be disposed of with household waste at
the end of its service life. Disposal can take place at appropriate collection points in your country. Dispose of
the device in accordance with the Waste Electrical and Electronic Equipment EC Directive – WEEE (Waste
Electrical and Electronic Equipment). If you have any questions, please contact the local authority responsible for
disposal.
- To turn off the pulse oximeter, wait 10 seconds. The pulse oximeter switches off automatically.
Applied part type BF
IP22, type BF applied part
"beurer HealthManager" app is not
activated or Bluetooth® is switched off
in the smartphone settings.
1. Slide open the battery
compartment cover.
normal range
• You must dispose of the used, completely discharged batteries via specially marked collection containers,
hazardous waste collection points or via the electronics retailer. You are legally obliged to dispose of the
batteries.
Fingertip must have the following dimensions:
width between 10 - 20 mm.
- accessories supplied with this product which wear out or become damaged through normal use.
accuracy
For speedy processing, please use our contact form on the website www.beurer.com under the heading 'Service'.
Android is a trademark of Google LLC.
no strong light source (e.g. fluorescent lamp or direct sunlight) are located. • In people who have low
blood pressure, suffer from jaundice or are taking vascular medication
1. Slide the narrow end of the lanyard through the holder
as shown.
Insert batteries again. If readings are still
not displayed after correctly installing the
batteries, contact customer service.
Repairs or a complete replacement do not extend the warranty period under any circumstances.
The orientation of the display (portrait, landscape) is done automatically. This allows you to view the values on the display
at any time
Turn on the function key.
• Danger of explosion! Do not throw batteries into fire.
Switch Bluetooth® on (ON) on the device as
described in Chapter 8.
The guarantee also applies without prejudice to mandatory statutory liability regulations.
Claims from product liability or other mandatory legal liability provisions exist).
1. Slide a finger into the finger hole of the pulse oximeter
as shown. Keep your finger steady.
,
Weight
Specifications are subject to change without notice for update reasons.
The function button of the pulse oximeter has a total of 4 functions:
Disposal according to electrical and
Google Play and the Google Play logo are trademarks of Google LLC.
German law applies.
1500-2500 m
Measuring finger is too big or too small.
data transmission
- To return to measurement, press and hold the function button for 5 seconds.
Specifically excluded from this warranty are - wear and tear
resulting from normal use or consumption of the product;
Follow the instructions
This product meets the requirements of
the applicable European and national
guidelines.
oximeter starts to measure. Do not move during the
measurement process.
Observe the warning and safety
instructions in Chapter 5.
The following warranty conditions do not affect the statutory warranty obligations of the seller from the purchase
contract with the buyer.
Classification / Measures to be taken
2 AAA batteries enable approx. 2 years of operation with 3 measurements per day
(60 seconds each).
• Protect batteries from excessive heat.
If the buyer would like to report a warranty claim, they should first contact Beurer Customer Service: Beurer
GmbH, Service Center Tel: +49 731 3989-144
- Products that have been used, cleaned, stored or serviced improperly and/or contrary to the provisions of the operating
instructions, as well as products that have been opened, repaired or modified by the buyer or a service center not
authorized by Beurer;
Non-invasive measurement of arterial oxygen saturation of hemoglobin and pulse
rate on the finger
Note on important information
- The "beurer HealthManager" app must be activated for the transfer.
The pulse oximeter
shows no readings
AAA batteries
- Consequential damage caused by a defect in this product (in this case, however,
- Briefly press the function button to activate (ON) or deactivate (OFF) Bluetooth®.
A claim under the guarantee can only be considered if the buyer can present - a copy
of the invoice/purchase receipt and - the original product to Beurer or an authorized
Beurer partner.
Manufacturer
Consult a doctor.
99-94
The serial number can be found on the device or in the battery compartment.
1x lanyard, 1x belt pouch, 1x this manual
5. Battery indicator
battery life
measuring range
• Do not disassemble, open or shred batteries.
Apple and the Apple logo are trademarks of Apple Inc., registered in the U.S. and other countries. App Store is a service
mark of Apple Inc., registered in the U.S. and other countries.
a soft cloth dampened with medicinal alcohol.
measured value jumps
classification
The batteries in the pulse oximeter are
empty.
2x 1,5 V
CE marking
• If a battery leaks, put on protective gloves and clean the battery compartment with a dry cloth.
2. Press the function key. the pulse
Insufficient blood flow to the measuring
finger.
Beurer GmbH, Söflinger Straße 218, D-89077 Ulm (hereinafter referred to as "Beurer") grants a guarantee for this
product under the following conditions and to the extent described below.
device occur.
- Products purchased as 2nd choice or used items;
the device to prevent possible battery leakage.
Permissible operating conditions +10°C to +40°C, ÿ75% relative humidity, 700–1060 hPa ambient
Quelle: Hackett PH, Roach RC: High-Altitude Medicine. In: Auerbach PS (ed): Wilderness Medicine, 3rd edition;
Mosby, St.Louis, MO 1995; 1-37.
serial number
a notice
- Bluetooth® is automatically activated.
Measurement
interruptions or high
93-90
We are pleased that you have chosen a product from our range. Our name stands for high quality and thoroughly tested
quality products in the areas of heat, weight, blood pressure, body temperature, pulse, gentle therapy, massage, beauty,
baby and air. Please read these instructions for use carefully, keep them for later use, make them accessible to other
users and follow the instructions.
alarm suppression
Measurement result SpOÿ (oxygen saturation) in %
The buyer then receives more detailed information on how to process the guarantee case, eg where to send the product
free of charge and which documents are required.
Replace the batteries.
Batteries not inserted correctly.
Lanyard Holder
• Do not use rechargeable batteries!
Any use of these brands by Beurer GmbH is under license. Other trademarks and trade names are those of their
respective owners.
Source: Based on “Windisch W et al. S2k guideline: Non-invasive and invasive ventilation as therapy for chronic respiratory
insufficiency Revision 2017; Pneumology 2017; 71: 722795"
Damage to device/accessories
Replace the batteries.
customer arise
Approx. 27 g (without batteries)
Dimensions
• Pay attention to the plus (+) and minus (-) polarity markings.
This guarantee only applies to products that the buyer has purchased as a consumer and uses exclusively for
personal purposes within the framework of domestic use.
health
Insert batteries into the pulse
oximeter as shown (with the correct
polarity).
be usable to a limited extent. As a result, e.g. error messages or failure of the display/
Altitude sickness, adaptation recommended
water
used up (e.g. batteries, rechargeable batteries, cuffs, seals, electrodes, lamps, attachments, inhaler accessories);
Store the pulse oximeter in a dry environment (relative humidity ÿ95%). Excessive humidity can shorten the life of the
pulse oximeter or damage it. Store the pulse oximeter in a place where the ambient temperature is between -40°C and 60°C.
- With the pulse oximeter switched on, press and hold the function button for 5 seconds to access the Bluetooth®
setting. "ON" or "OFF" appears in the display.
The Bluetooth® word mark and logo are registered trademarks owned by Bluetooth SIG, Inc.
Pulse oximeter shows
cedeclarationofconformity.php.
• Use only the same or equivalent type of battery. • Always replace all batteries
at the same time.
Dear Customer,
batteries off.
power supply
- Damage occurring on the transport route between the manufacturer and the customer or between the service center and
L 58,5 mm x B 31 mm x H 32 mm
Bluetooth® on the device is not
activated (OFF).
CISPR 11, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-8) and is subject to special precautions regarding electromagnetic
compatibility. Please note that portable and mobile HF communications equipment can affect this device. You can request
more detailed information from the customer service address provided.
The following symptoms occur more frequently in people with a low oxygen saturation value: shortness of breath, heart
rate increase, loss of performance, nervousness and sweating. A chronic and known reduced oxygen saturation requires
monitoring by your pulse oximeter under medical supervision. An acutely reduced oxygen saturation, with or without
accompanying symptoms, must be clarified immediately by a doctor, it can be a life-threatening situation. The pulse
oximeter is therefore particularly suitable for high-risk patients such as people with heart disease and asthmatics, but also
for athletes and healthy people who move at high altitudes (e.g. mountaineers, skiers or sports pilots).
Possible Cause
function key
Minute)
Security notice on possible
fix
Consult a doctor urgently
shear results.
cardiac arrhythmias.
List of supported smartphones / tablets
1x PO 60 pulse oximeter, 2x 1.5 V AAA batteries
Read these instructions for use carefully! Failure to follow the instructions below can cause personal injury or damage to
property. Keep the instructions for use and make them accessible to other users. Pass on these operating instructions if
the device is passed on.
measurement method
an abnormal hemoglobin occurrence is to be expected with a false measurement. This applies in particular to carbon
monoxide poisoning and methemoglobin poisoning, which are caused, for example, by the administration of local
anesthetics or when there is a methemoglobin reductase deficiency.
Warning of the risk of injury or
danger to your
The batteries in the pulse oximeter are
weak or dead.
Failure to follow the instructions below can result in erroneous measurements or measurement failure.
No altitude sickness (usually)
The Beurer PO 60 pulse oximeter is used for non-invasive measurement of arterial oxygen saturation (SpO2 ) and heart
rate (pulse rate). The oxygen saturation indicates what percentage of the hemoglobin in the arterial blood is loaded with
oxygen. It is therefore an important parameter for assessing respiratory function. The pulse oximeter uses two light beams
of different wavelengths to measure, which hit the finger inside the housing. A low oxygen saturation value is mainly due
to diseases (respiratory diseases, asthma, cardiac insufficiency, etc.).
Never hold the pulse oximeter under water, otherwise liquid can penetrate and damage the pulse oximeter.
- Short press the function button to turn on the pulse oximeter.
• If the device is not going to be used for a long time, remove the batteries from the battery compartment.
dispose of household waste
ments covered in the housing.
DANGER
Problem
Critical area:
4. Pulses
transport conditions
Pulse 30 - 250 bpm, ±2 beats/minute
finger opening
AFTER 60
WARNING
Bare infrared light from the pulse oximeter is harmful to the eyes.
The worldwide guarantee period is 5 years from the start of the purchase of the new, unused product by the buyer.
Device protected against foreign bodies
ÿ12.5 mm and against slanting drips
Pulse rate (beats per
Permissible operating temperature
and humidity
Beurer guarantees the flawless functionality and completeness of this product.
Kompatibel mit Bluetooth® 4.0 Smartphones / Tablets
3. Pulse wave (plethysmographic wave)
• In order not to falsify the measurement result, people should be in the immediate vicinity of the pulse oximeter
• Do not look directly into the inside of the housing during the measurement process. The red light and the invisible
• Clean the housing and the rubberised inner surface of the pulse oximeter after each use
• In patients who have received clinical dyes in the past and in patients with
• The device may only operate in the presence of electromagnetic disturbances
• If the pulse oximeter display shows a low battery condition, replace the battery
• If you will not be using the pulse oximeter for more than a month, remove both batteries
• This device is not intended to be used by persons (including children) with restricted physi
• Check that all parts specified in the scope of delivery are included.
• Prolonged use of the pulse oximeter can cause pain in persons with circulatory disorders. Therefore, do not use
the pulse oximeter on a finger for more than about 2 hours.
• We hereby confirm that this product complies with the European RED Directive 2014/53/EU. the
• Check the pulse oximeter regularly to ensure that there is no visible damage before use and that the batteries are
sufficiently charged. If in doubt, do not use it and contact Beurer customer service or an authorized dealer.
• The pulse oximeter displays an instantaneous reading at a time, but cannot provide a continuous over
• The pulse oximeter does not have an alarm function and is therefore not suitable for medical evaluation
• Do not use any additional parts that are not recommended by the manufacturer or offered as accessories.
• Protect the pulse oximeter from dust, shock, moisture, extreme temperatures and explosives
• Do not carry self-diagnosis or treatment based on the measurement results without consultation
• Under no circumstances may you open or repair the device, as otherwise it cannot be guaranteed that it will
function correctly. Failure to do so will void the warranty. For repairs, contact Beurer customer service or an
authorized dealer.
• Using this device in close proximity to other devices or with other devices in gesta
• Non-observance can lead to a reduction in the performance characteristics of the device.
• Keep your hand, fingers and body still during the measurement process.
• This device conforms to European standards EN60601-1 and EN60601-1-2 (compliance with
• In the case of people with cardiac arrhythmia, the measured SpOÿ and heart rate values may be incorrect or the
measurement may not be possible at all.
• The use of accessories other than those specified or provided by the manufacturer of this device can result in
increased electromagnetic interference emissions or reduced electromagnetic interference immunity of the
device and lead to incorrect operation.
• There should be no nail polish, artificial nails or other cosmetics on the measuring finger. • When
using the measuring finger, ensure that the fingernail is short enough for the fingertip to touch the sensor element
• Pulse oximeter readings are too high in case of carbon monoxide poisoning.
• The device complies with the EU directive for medical devices 93/42/EEC, the Medical Devices Act and the
standard DIN EN ISO 80601-2-61 (medical electrical devices - special specifications for the basic safety and
the essential performance features of pulse oximeters for the medical Use).
• Keep portable RF communications equipment (including peripherals such as antenna cables or external
antennas) at least 30cm away from any part of the equipment, including any cables provided. Non-observance
can lead to a reduction in the performance characteristics of the device.
Pulsoximeter
GERMAN
98 65
AFTER 60
Beurer GmbH • Soeflinger Strasse 218 • 89077 Ulm, Germany
3
2
4
PR bpm
1
5
www.beurer-healthguide.com
IP 22
%SpOÿ
www.beurer.com • www.beurer-gesundheitsratgeber.com
WARNING
16. Specifications
Notes on Electromagnetic Compatibility • The device
is suitable for operation in all environments specified in these operating instructions,
including the domestic environment.
15. What to do if there are problems?
13. Retention
14. Disposal
17. Warranty/Service
6. Device Description
5. Warnings and Precautions
8. Service
1. Scope of delivery
11. Assess measurement results
Display description
3. To get to know each other
2. Intended use
9. System requirements for the "beurer HealthManager" app
12. Cleaning / Maintenance
7. Commissioning
10. Transmission of the measured values via Bluetooth® low energy technology
4. Explanation of symbols
%SpO2 PRbpm
Note
Bluetooth® must be activated (ON) for transmission.
function key
7.2 Fasten the neck strap
a notice
Notes on handling batteries • If
liquid from a battery cell contacts your skin or eyes, wash the affected area with
water and seek medical attention.
7.1 Insert batteries
Altitude dependent drop in oxygen saturation
DANGER:
WARNING
DANGER:
a notice
Machine Translated by Google