background image

 
 

 

Connect

the

water

supply

pipes  

to

the

flexi

-

pipes

on

the

rear 

of the panel

,

ensuring

hot

is on  

the left

and that

the

seals

are  

fitted

,

then tighten the nut. 

 

Ensure

that

flexi

-

pipes

cannot 

become

kinked

or

flattened

.

 

 

Once connected

lift

and

hang 

the assembly onto

the

hanging 

brackets

.

 

 

 

 

 

 

Fit

the seal into

the

nut end

of the

shower hose and 

connect

the

nut

to

the

outlet

on

the

hand

shower

 

holder

and

tighten

,

if using a spanner

,

place a cloth  

around

the

nut

to

prevent

damage

.

 

 

Place the second

seal

into

the

cone

end

of

the  

shower

hose

and

connect

this

to

the

hand

shower 

and

tighten

.

 

 

Place the cone

of the

hose

into

the

holder

.

 

 

Installation

is

then

complete

,

the product should

then  

be commissioned

,

by turning on

the

water supply and   

checking

for

leaks

.

 

3

3

1

2

3

1

2

Summary of Contents for Luni BeBa 28181

Page 1: ...Please note Image is for illustrative purposes only and may differ slightly to the actual product Multi person assembly Tools required We always recommend using professional tradespeople to install your product V1_26 08 21 Congratulations on your purchase ...

Page 2: ... Awards UK the Digital Entrepreneur Awards and being placed on The Sunday Times Fast Track 100 We hope your new product goes above and beyond your expectations However should any problems occur please log in to your account and contact our customer services team via your self serve portal betterbathrooms com CustomerAccount Login contact us via betterbathrooms com content contact us Important info...

Page 3: ...Contents Parts Diagrams P4 Tools required P5 Installation P5 Using P9 Troubleshooting P9 Maintenance P10 Cleaning P12 3 ...

Page 4: ...Off Control Handle 5 Temperature Control Handle 6 Diverter Valve 7 On Off Cartridge 8 Thermostat inc Stop Ring 9 Temperature Dial 10 Wall Screws x 4 11 12 Wall Hanging Bracket x 2 13 Hand Shower 14 Hose Seals x 2 15 Shower Hose 16 Overhead Bolt x 4 17 Washers x 8 18 Nut x 4 16 17 18 1 2 3 5 9 19 10 6 8 11 20 15 12 14 13 4 7 19 20 Handset Holder and Fi ngs Flexi pipes x 2 Wall Plugs x 4 ...

Page 5: ...cold on the right set approximately at the height and width shown below The supply pipes should have a male end to connect to the 1 2 female nut on the flexi pipes Before commencing installation and with the tray or bath installed to accept the water turn on the water supply to the water pipes and flush the system for a minimum of 15 seconds to remove any debris in the system 1000mm 100 150mm ON ...

Page 6: ... If drilling into tile it is recommended to tape the wall to prevent the drill from slipping Drill the wall 35mm deep using a 6mm drill bit Insert the wall plugs and tap flush to the finished wall surface Hold the wall hanging bracket to the wall over the drilled holes and secure using the wall plugs provided 780 50 mm 1000 2 mm 20mm 35mm 6mm 2 3 1 ...

Page 7: ...ng the seal is fitted connect the pipe which runs from the mixer and which will connect to the holder and tighten the nut Connect the overhead shower to the panel Insert the water pipe from the shower head X 1 2 3 4 5 to shower panel body using the jubilee and tighten onto the outlet using a screwdriver 1 2 3 4 5 Position the shower head onto the panel and align the holes Place a washer onto the bo...

Page 8: ...ts Fit the seal into the nut end of the shower hose and connect the nut to the outlet on the hand shower holder and tighten if using a spanner place a cloth around the nut to prevent damage Place the second seal into the cone end of the shower hose and connect this to the hand shower and tighten Place the cone of the hose into the holder Installation is then complete the product should then be com...

Page 9: ...ed water pressure water pressures need to be balanced for correct function 2 Limescale build up or debris in the thermostat this will require cleaning 3 Faulty thermostat 4 Product requires re calibration Water temperature either very cold or very hot no gradual mix 1 This is due to the water supplies being connected to the wrong inlet on the tower these need to be switched so that the correct wat...

Page 10: ...are not balanced you will need to consult a plumber to either reduce the cold pressure but ensuring the pressure do not fall below the minimum or a pump may need to be installed to balance the pressures 2 To remove the thermostat for cleaning or replacement first turn the shower on then turn off the water supply to the tower by the isolation valves doing this releases the pressure inside the unit b...

Page 11: ...e valve 3 Using a spanner and taking care not to damage the panel surface remove the retaining nut 4 Once this is removed pull the valve from the panel either clean the valve or replace as necessary 5 Re fit the components and fully tighten the retaining nut to prevent any leaks 1 2 3 4 5 8 9 6 10 11 7 Flat blade screwdriver Plier Allen wrench 2 5 m m ...

Page 12: ...12 Cleaning To maintain the surface of your product wipe with a clean damp cloth and wipe dry do not use any abrasive cleaning agents or materials It is recommended to wipe and dry on a regular basis ...