PeroxiDraw
™
Dispenser
INSTALLATION INSTRUCTIONS
I-883
Pg. 2 of 6
05/05
B. CHEMICAL INJECTION ADJUSTMENT:
WARNING: USE CARE WHEN HANDLING HAZARDOUS CHEMICALS.
Chemicals feed rates are controlled by metering tips that are pretipped into the selector valve barbs and the 4 GPM
proportioner inlet barb. If using a different tip is desired, choose a tip from the chart below.
TABLE 1
1 GPM FLOW RATE PROPORTIONER, 1/4” I.D. TUBING
Metering Tip Color
Oz/Gal Ratio
Tan 1.03
125-1
Orange 1.24
103-1
Turquoise 1.43 89-1
Pink 2.47
52-1
Light Blue*
3.05
42-1
Brown 3.48
37-1
Red 4.38
29-1
White 5.33
24-1
Green 6.38
20-1
Blue 6.77
19-1
Yellow 9.90
13-1
Black 15.00
9-1
Purple 24.94
5-1
Gray 35.94
4-1
No Tip
73.21
2-1
TABLE 2
4 GPM FLOW RATE PROPORTIONER, 1/4” I.D. TUBING
1 cps
Metering Tip Color
Oz/Gal Ratio
Tan 0.33
387-1
Orange 0.42
307-1
Turquoise 0.51
251-1
Pink 0.78
165-1
Light Blue*
0.87
147-1
Brown 0.99
129-1
Red 1.37
93-1
White 1.52
84-1
Green 1.72
74-1
Blue 2.13
60-1
Yellow 3.05
42-1
Black 4.50
28-1
Purple 7.75
17-1
Gray 9.86
13-1
No Tip
19.63
7-1
NOTE:
•
*Metering tip color was formerly clear
•
All induction rates are base on a water pressure of 40 psi