14
1. ELECTRICAL SYSTEM SAFETY
The machine is equipped with a thermal breaker unit that has a manual reset.
The brushes motor is re-enabled by resetting the thermal breaker unit located
within the handle.
If the machine stops repeatedly contact the BETCO technical assistance center
at 877-856-5954.
2. INSUFFICIENT WATER ON THE FLOOR
A. Verify that the solution tank is clean.
B. Verify that the solenoid valve switch is turned on.
C. Verify the quick disconnect is properly connected.
D. Verify the adjustment of the ball valve that supplies water.
E. Verify the vent pin on the solution tank cap is lowered.
3. THE MACHINE DOES NOT CLEAN WELL
A. Check the condition of the brushes or pad. Replace them as required.
Brushes must be replaced when the tufts are roughly 5/8” (15 mm) long.
4. THE SQUEEGEE DOES NOT DRY THE FLOOR
A. Verify that the squeegee blades are clean.
B. Verify that the vacuum hoses are properly installed and seated on the
squeegee.
C. Verify the vacuum hose nozzle is clean.
D. Replace worn squeegee blades.
5. EXCESSIVE FOAM PRODUCTION
Verify that low-foam detergent is being used. Add defoaming chemical to the
recovery tank.
More foam is generated when the fl oors are not very dirty. Dilute the detergent
more when cleaning fl oors that are not very dirty.
TROUBLESHOOTING GUIDE
To Order Parts Call 1-888-702-5326 - https://monsterfloorequipmentparts.com