7
1. INSPECT THE MACHINE
Before each use inspect the machine, hoses, and cleanliness and completeness.
Ensure the spray nozzles on the cleaning tool are tight and that the float ball in
the recovery tank is clean and operational.
2. SECURE RECOVERY TANK
Close the clear, screw-on lid to the recovery tank and make sure the drain hose
caps is also screwed on tightly.
3. FILL SOLUTION TANK
Fill the solution tank with clean water. The heater on the H series is designed
to provide nearly instant hot water for cleaning. If you use warm water in the
solution tank it will increase the heaters efficiency.
Never use water above 120° F (49° C) in the solution tank.
4. SAFELY PLUG IN MACHINE
Turn off all the switches. Plug the power cords into properly grounded outlets. If
the machine is equipped with two cords, do not connect both cords to the same
outlet.
NOTE:
This machine is equipped with a seperate circuit locator light. This
feature will inform the operator when the cords are plugged into seperate cicuits,
thereby helping to prevent tripped circuit breakers. If the green light does not
illuminate when both cords are plugged in, it means the cords are on the same
circuit. Try other outlets with one of the cords until you get the indicator light to
come on
.
5. CONNECT HOSES
Connect the solution hose and the vacuum hose to the machine and to the
cleaning tool. Turn on the pump switch and depress the trigger on the tool for a
few seconds to fill the heater and lines with water.
MACHINE OPERATION