4)
The height of the dental wheel is very important and in
combination with a correctly levelled wing ensures a trouble-free
operation (See set up Menu 8 Para 4).
The normal rule is 1.5 mm space between dental wheel and dental
rack.
Once the adjustment has been done. Move the wing over the complete
length of movement observing the dental wheel and rack.
Should meshing problems occur in certain positions, these can be
regulated by either moving the dental rack up or down on the under-
beam (oblong holes).
5)
Disengage the gearbox by turning the red sling
clockwise
6)
Move the wing back and forth by a small amount. Check that the dental
wheel is engaged over the whole width of the dental rack. If not, adjust
the dental rack.