Beta 601CA Instructions For Use Manual Download Page 3

8

 

ISTRUZIONI PER L’USO 

I

INSTRUCTIONS FOR USE

EN

• Remove the flat batteries, and install the new batteries, paying attention to the polarity (2 AAA batteries).

• Close the battery compartment, and tighten the four screws.

• Remove the batteries, if the digital gauge is not used for an extended period.

• If the battery is flat, the battery symbol will be shown on the display.  

 

DIGITAL GAUGE SAFETY

• Do not drop or hit the digital gauge. 

• Do not use the digital gauge in humid or wet environments.

• To clean the digital gauge, use a dry cloth. Do not use alcohol or diluents.

• Do not place the digital gauge near magnetic fields.

• Do not modify the digital gauge. Changes may affect operation.

TECHNICAL DATA

KEY TO SYMBOLS

a: LED indicators

b: buzzer

c: digital display

d: start of measurement / menu button (C)

e: unit selection button (U/S)

f: pulsante memoria  (M)

f: memory button (M)

+ button   

-  button  

h: battery compartment

DISPLAY

PRECISIONE ANGOLO

TORQUE MEASURING RANGETORQUE 

ACCURACY

RESOLUTION

SCALE

SQUARE DRIVE

SELECTABLE UNITS OF MEASUREMENT

PROGRAMMABLE VALUES

STORED VALUES

POWER SUPPLY

OPERATING TEMPERATURE

STORAGE TEMPERATURE

HUMIDITY

WEIGHT

0 ---> 999,0

± 2°  

10 ÷ 200 N.m

Clockwise ±3%  - Anticlockwise ±4%    

0.1°

360° (increment 0.1°)

1/2"

N.m, ft.lb, in.lb, kg.cm, gradi

9

50 max

2 AAA batteries

-10°C ÷ 60°C

-20°C ÷ 70°C

max 90% 

260 g

>

>

601CA.indd   8

08/09/16   10:54

Summary of Contents for 601CA

Page 1: ... ISTRUZIONI PER L USO I INSTRUCTIONS FOR USE EN MODE D EMPLOI F GEBRAUCHSANWEISUNG D INSTRUCCIONES E INSTRUÇÕES DE USO PT GEBRUIKSAANWIJZING NL INSTRUKCJA OBSŁUGI PL h e f d a b c 601CA indd 1 08 09 16 10 54 ...

Page 2: ...he digital gauge must not be used for any applications other than recommended ones WORK AREA SAFETY Do not operate the digital gauge in environments containing potentially explosive atmospheres because sparks may be generated which can ignite the dust or fumes Keep children away from the digital gauge Do not use the digital gauge near flammable material DIGITAL GAUGE SAFETY Before use check that t...

Page 3: ...ts Do not place the digital gauge near magnetic fields Do not modify the digital gauge Changes may affect operation TECHNICAL DATA KEY TO SYMBOLS a LED indicators b buzzer c digital display d start of measurement menu button C e unit selection button U S f pulsante memoria M f memory button M button button h battery compartment DISPLAY PRECISIONE ANGOLO TORQUE MEASURING RANGETORQUE ACCURACY RESOLU...

Page 4: ...tightening process is resumed the value will be calculated from the value reached before To reset the device and start a new measurement press button C If the device is not used for approximately 2 minutes the device will automatically turn off SETTING UP MENU Press button C to turn the gauge on Keep button U S pressed to enter the configuration menu Press button U S several times to enter the men...

Page 5: ...he value has not been set correctly Press button C to repeat the operation Do not move the gauge while setting it Er5 indicates that the gauge is not working correctly Proceed with the RESET Er indicates that the gauge was rotated too quickly during a measurement Press button C to repeat the operation Full indicates that no data can be stored in the memory because the memory is full Delete some of...

Page 6: ...ot cover defects due to wear misuse or breakdowns caused by blows and or falls In addition this warranty will no longer be valid if any changes are made or if the digital gauge is forced or sent to the customer service in pieces This warranty explicitly excludes any damage to people and or things whether direct or consequential We hereby declare assuming responsibility that the described product c...

Reviews: