the up, down, left, right direction keys and "Enter" key to set frequency parameter,
select "OK" and press "Enter" button to confirm.
4. Set offset
Press
F4
button to enter the second page. Press
F2
to select
Offset
, then use the up,
down, left and right direction keys to adjust the frequency, press
F2
button to open the
digital keyboard again, use the up, down, left, right direction keys and "Enter" key to
set frequency parameter, select "OK" and press "Enter" button to confirm.
5. Set duty cycle
enter the second page. Press
F3
to select
Duty
, then use the up, down, left and right
direction keys to adjust the frequency, press
F3
button to open the digital keyboard
again, use the up, down, left, right direction keys and "Enter" key to set frequency
parameter, select "OK" and press "Enter" button to confirm.
6. Generate an arbitrary waveform
It is necessary to edit the arbitrary waveform in connection with the software and
download it into the machine. There are 4 arbitrary wave positions, and each position
can permanently store an arbitrary wave.
7. After setting the waveform parameters, press the
button to turn on or off the signal
output. The output waveform of the signal generator can be observed through an
oscilloscope.
Output the sine waveform
Output a sine waveform with 10KHz/2.5Vpp as follows:
1. Press
AWG
button to enter the waveform generator function interface.
2. Press
F1
to select “Sine”;
3. Frequency: First press
F2
button to select
Frequency
, then use the up, down, left
and right direction keys to adjust the frequency. Second press
F2
button to open the
digital keyboard again, use the up, down, left, right direction keys and "Enter" key to
set frequency parameter, select "OK" and press "Enter" button to confirm. Set the
frequency to 10KHz;
4. Amplitude: First press
F3
button to select
Amplitude
, then use the up, down, left and
right direction keys to adjust the amplitude. Second press
F3
button to open the
digital keyboard again, use the up, down, left, right direction keys and "Enter" key to
set amplitude parameter, select "OK" and press "Enter" button to confirm. Set the
amplitude to 2.5V;
5. Offset: Press
F4
to enter the second page. First press
F1
button to select
Offset
,
then use the up, down, left and right direction keys to adjust the offset. Second press
F1
button to open the digital keyboard again, use the up, down, left, right direction
72
Summary of Contents for 1760DGT/2
Page 1: ...1760DGT 2 Multimetro digitale con oscilloscopio Manuale d uso 1 ...
Page 44: ...1760DGT 2 Digital multimeter with oscilloscope User Manual 44 ...
Page 75: ...8 Connect Gen Out connector to oscilloscope for observation 75 ...
Page 85: ...1760DGT 2 Multimètre numérique avec oscilloscope Manuel de l Utilisateur 85 ...
Page 117: ...8 Connectez le connecteur Gen Out à l oscilloscope pour l observation 117 ...
Page 127: ...1760DGT 2 Digitalmultimeter mit Oszilloskop Benutzerhandbuch 127 ...
Page 159: ...8 Schließen Sie den Gen Out Stecker zur Beobachtung an das Oszilloskop an 159 ...
Page 169: ...1760DGT 2 Multímetro digital con osciloscopio Manual de usuario 169 ...
Page 200: ...8 Conecte el conector Gen Out al osciloscopio para observación 200 ...
Page 210: ...1760DGT 2 Multímetro digital com osciloscópio Manual do usuário 210 ...
Page 241: ...8 Conecte o conector Gen Out ao osciloscópio para observação 241 ...
Page 251: ...1760DGT 2 Digitale multimeter met oscilloscoop Handleiding 251 ...
Page 282: ...8 Sluit de Gen Out connector aan op de oscilloscoop voor observatie 282 ...
Page 292: ...1760DGT 2 Multimetr cyfrowy z oscyloskopem Instrukcja obsługi 292 ...
Page 323: ...8 Podłączyć złącze Gen Out do oscyloskopu w celu obserwacji 323 ...
Page 333: ...1760DGT 2 Digitális multiméter oszcilloszkóppal Használati utasítás 333 ...
Page 365: ...8 Csatlakoztassa a Gen Out csatlakozót az oszcilloszkóppal megfigyelés céljából 365 ...