12
TECHNICAL DATA
BATTERY CHARGER FEATURES AND OPERATING MODES
CHARGE CYCLES
The charge cycles of the new battery chargers have been specially developed to optimize the charge of all types of batteries
available in the market. The numerous constructional technologies of currently available batteries require different charging
curves to ensure correct and complete charging. These battery chargers extend the lives of your batteries because they provide
each with the proper charge cycle.
1 • Battery state diagnosis: “A1”
The battery charger tests the state of charge of the
battery to charge.
2 • Charging: “Deep discharge recovery”
The battery charger starts charging using a pulsating
current until the battery reaches optimal voltage and
power levels before starting the second charging step.
3 • Charging: “soft I”
The battery is charged at a reduced, constant current.
4 • Charging: “I”
The battery is charged at a constant current until the
battery reaches its maximum voltage.
5 • Charging: “U0”
The battery is charged at a stabilised voltage until
current reaches minimum values.
6 • Charging: “Recovery” *
Only with battery charger set to RECON: the battery is
charged deeply at a constant current and increasing
voltage to boost the charge capacity of the battery.
7 • Battery state diagnosis: “A2”
The battery charger tests the state of efficiency of the
charged battery.
8 • Charging: “U”
The battery charge is maintained at a reduced, constant
voltage.
9 • Charging: “Up”
The battery charge is maintained with pulses of current
(provided constantly).
ISTRUZIONI PER L’USO
I
OPERATION MANUAL AND INSTRUCTIONS
EN
FOR USE WITH BATTERIES
RATED VOLTAGE
CHARGING VOLTAGE
ABSORBED POWER
DEGREE OF PROTECTION
12 or 24V, 5Ah to 800Ah
Batteries: WET – GEL - AGM - LITIO LiFePO4
220-240V 50/60Hz
12 - 24V
375 Watt
IP20