SOFTWARE APPLICATION GUIDE

1.3> Program: Obtain the information of currently used configuration file (Disconnection status),or the 

         information of current program in the equipment(Connection status).

         On disconnection status, only 

Display Current Program No

Display Current Program Name

 ,

"

" "

"

        

Edit Current Program Name

 and 

Load Factory Default Configuration

 may be valid. All 

"

"

"

"

         changes do not affect the equipment internal program settings.

         On connection status, all items are valid under the  Program menu. If selecting the

Edit Current

 

"

"

         Program Name

 command, the current program name auto saved in the equipment;

"

         If selecting the 

Load Factory Default Configuration 

 command, the current program is overwrite 

"

"

        by the default setting automatically (

! Attention Please: this operation will overwrite the current 

        program configuration, before executing this operation, please make sure you really ready to load 
        factory default settings

). Details of other function items (such as

List Program & Recall

 and 

Save 

"

"

"

        as current program in device

)under the  Program  menu, please refer to following description.

"

"

"

1.4> Device: Modify the device information, and saved in the equipment automatically, only valid on 

         connection status;

1.5> Help: the control software version information.

2.Connecting the device.

2.1> Three hardware connection solution(USB,RS-232,RS-485) are available for your connecting;

2.2> After connected the device with computer port by connector, Click the "Communications", select 

       "E nable Communications" command to start the connecting. See Figure 2:

The software will search the connected (hardware connection) device automatically, 

Search 

Device...

 will be shown at the bottom of interface's status bar, see Figure 3:

"

S1200Na

Summary of Contents for S1200Na

Page 1: ...ED B3 MA 070308 001 S1200Na USER M ANUAL...

Page 2: ...1 2 6 1 ACOUSTIC FEATURES SPECIFICATION CONTENTS PRODUCT FEATURES AMPLIFICATION MODULE CONTROL SOFTWARE 7 INSTALLATION SAFETY INFORMATION WARRANTY DIMENSIONS APPLICATION EXAMPLES 9 8 10 11 12...

Page 3: ...table for any sound reinforcement monitor and sound compensation of big installation project or living performance event PRODUCT FEATURES SPECIFICATION LF 12 1 MF 12 1 HF 1 1 7 45Hz 20kHz 132dB 60 x60...

Page 4: ...5 00 1k 2k 5k 1 0k 2 0k 20 Hz 1 3 0 d B S 3 6 0 0 D eg 1 2 0 2 5 2 0 1 1 0 1 4 4 0 1 0 0 3 6 0 9 0 7 2 0 8 0 1 8 0 C LIO 2 50 1 00 2 00 5 00 1k 2k 5k 1 0k 2 0k 20 Hz 1 3 0 d B S 3 6 0 0 D eg 1 2 0 2...

Page 5: ...se 2nd Distortion 3rd Distortion 50 1 00 2 00 5 00 1k 2k 5k 1 0k 2 0k 40 Hz 1 20 d B 1 8 0 0 D eg 1 1 0 1 0 8 0 100 3 6 0 9 0 3 6 0 8 0 1 08 0 70 1 80 0 C LIO 0 10 20 30 40 50 dB 2 00 5 00 1k 2k 5k 1...

Page 6: ...0 270 300 330 0 30 60 90 120 150 180 210 240 270 300 330 0 30 60 90 120 150 180 210 240 270 300 330 0 30 60 90 120 150 180 210 240 270 300 330 0 30 60 90 120 150 180 210 240 270 300 330 0 30 60 90 120...

Page 7: ...240 270 300 330 0 30 60 90 120 150 180 210 240 270 300 330 0 30 60 90 120 150 180 210 240 270 300 330 0 30 60 90 120 150 180 210 240 270 300 330 0 30 60 90 120 150 180 210 240 270 300 330 0 30 60 90 1...

Page 8: ...ory with Germany computer aided design software and testing system according to IEC standard Beta Three Elder Audio Manufacture Co Ltd No 230V T6 3AL 50Hz 60Hz ON OFF RS 485 INPUT USB PEAK RS 232 LINE...

Page 9: ...if the computer has not the RS 232 interface you may use USB port after connection the computer will indicate that new device is found then you may install the USB driver located in driver directory o...

Page 10: ...n Please this operation will overwrite the current program configuration before executing this operation please make sure you really ready to load factory default settings Details of other function it...

Page 11: ...n the operation execute transmitting the parameters into Device s RAM if no further save into device operation the parameters will be lost after the device power off If user chose Upload Program Data...

Page 12: ...operation that you want 3 Recall or Save the configuration file When the device used in different places the different configuration file are necessary Two ways are available for user to recall or sav...

Page 13: ...For the file saved in the computer it may be recalled from Open under File menu Then connect the equipment choose Download program data to device in pop out dialog box see Figure 4 Picture 7 3 3 For t...

Page 14: ...ting it may be changed through clicking Edit current device information in device menu See Figure 9 Attention ID number is only available for number 1 10 that s to say only max 10 device may be connec...

Page 15: ...PC then modify those parameters that you want then select the Save As Current Program In Device command in Program Menu 13 SOFTWARE APPLICATION GUIDE Picture 11 6 Disconnection After finishing the adj...

Page 16: ...e Program No 1 has been saved as Program No 2 and the current program auto changed to No 2 and the Program No 1 just be uploaded to PC has not been changed S1200Na 4 Then on the Set Current Program Na...

Page 17: ...s the bellow figure S1200Na 5 Click OK button thus the Current Program Name on the main interface has been changed to my concert hall 6 Select List Program Recall command in Program menu the result in...

Page 18: ...program name on disconnection status and save as another file Then download the new config file into device then save as another program or current program into device Operation Example Steps 1 After...

Page 19: ...PLICATION EXAMPLES Edit Program Name to my modified program 3 then click OK button 3 Then select Save As command in File menu 4 In the File Name N frame input next hall asc then click Save S button S1...

Page 20: ...r downloading the config file into DEVICE only to RAM before select Save As Current Program In Device command the parameters have not saved into FLASH ROM 2 Select Save As Current Program In Device co...

Page 21: ...Click OK button then the parameters of config file next_hall asc have been saved as program No 4 in device The Current Program No and the Current Program Name are corresponding to File as bellow figur...

Page 22: ...20 S1200Na 423mm 721mm 416mm INSTALLATION DIMENSIONS Top view Front view Side view Back view 280mm 235mm...

Page 23: ...itional details are included in the Limited Warranty statement S1200Na Flying Hardware including enclosure mounted hardware and rigging accessories is guaranteed against malfunction due to defects in...

Page 24: ...S1200Na www beta3pro com...

Reviews: