For example:  

To set SP-1 to 123.456 

1)  Press the PAR key once 

2)  Press the SEL key to move the digit selection to the 1000ths position 

3)  Press RST key 6 times to increment the last digit to 6 

4)  Press SEL to move to the 100ths position 

5)  Press RST key 5 times 

6)  Press SEL to move to the 10ths position 

7)  Press RST 4 times 

8)  Press SEL to move to the ones position 

9)  Press RST key 3 times 

10) Press SEL to move to the tens position 

11) Press RST twice 

12) Press SEL to move to the hundreds position 

13) Press RST once 

14) Press PAR key until the length display is shown 

 

 

Part No. MAN/EN5400-0001 

Page 11 of 14 

                Revision B (Jun 2010) 

Summary of Contents for DataPro 500

Page 1: ...DATAPRO 500 OPERATOR GUIDE daily operation and routine maintenance www betalasermike com Manual Part Number MAN EN5400 0001 English Revision B Copyright Jun 2010...

Page 2: ...f Conformity 5 General Safety Information 6 Intended Use 6 Laser Safety Precautions 6 Labels and Safety Features 7 Introduction 8 Operation 8 Key Switch 8 Programmable Indicator 9 Fuses 12 Cleaning 12...

Page 3: ...its use and under conditions of its use EXCLUSIONS This warranty does not cover products which have been modified altered or repaired by any other party than Beta LaserMike or its authorized agents F...

Page 4: ...on earth point using adequately sized cable or other means of connection Where supplied or specified shielded interconnection cables must be employed with this equipment to ensure compliance with the...

Page 5: ...ide Declaration of Conformity DataPro 500 Operator Guide Declaration of Conformity Part No MAN EN5400 0001 Page 5 of 14 Revision B Jun 2010 Declaration of Conformity Part No MAN EN5400 0001 Page 5 of...

Page 6: ...ser beam in the optical sensor is very powerful and can permanently damage eyes not protected by laser safety glasses To avoid exposing yourself to hazardous radiation you must take these precautions...

Page 7: ...1 1986 For a copy of this document write to Laser Institute of America 13501 Ingenuity Drive Suite 128 Orlando Florida 32826 1 800 345 2737 Labels and Safety Features This section acquaints you with t...

Page 8: ...ator has a front panel LED that can be configured along with the LaserSpeed to indicate status information Operation Key Switch The DataPro 500 front panel key switch provides laser power and beam shu...

Page 9: ...Depending on the application the monitor is configured with different settings This section describes the general operation of the indicator and how to change settings In general operators do not con...

Page 10: ...a complete reference Key Parameters for Users This section only pertains to situations where the indicator is programmed with setpoints The counter should be configured with a lockout code so that onl...

Page 11: ...Press SEL to move to the 100ths position 5 Press RST key 5 times 6 Press SEL to move to the 10ths position 7 Press RST 4 times 8 Press SEL to move to the ones position 9 Press RST key 3 times 10 Pres...

Page 12: ...l power lines The fuse holder can hold two x 1 or two 5mm x 20mm fuses If a fuse is blown it should be replaced with a fuse of the same type Cleaning Use a soft cloth moistened with water for cleaning...

Page 13: ...laser to turn on Cooling heating may be required Run compressed air or 28 30 C water through sensor s coolant ports To avoid condensation the sensor temperature should not be allowed to go below dewpo...

Page 14: ...a contact person to discuss the instrument failure When returning equipment for service it is important to first obtain a Return Material Authorization RMA number The RMA number is needed for proper...