background image

4

Owner’s Manual

Name: Sierra RidgeAIR X6; Sierra RidgeAIR Pro X6

Model: 68077E; 68078E

WARNING:

 

KEEP ALL FLAME AND HEAT SOURCES AWAY FROM THIS TENT FABRIC

This tent meets the flammability requirements of CPAI-84. The fabric may burn if left in continuous contact 

with any flame source. The application of any foreign substance to the tent fabric may render the flame-resis-

tant properties ineffective.

IMPORTANT SAFETY INSTRUCTIONS

READ AND FOLLOW ALL INSTRUCTIONS

Keep all flames and heat sources away from this tent fabric. We recommend that you always position your 

tent upwind from a camp fire. This will reduce the chances of having embers land on your tent. In case of fire, 

please find the exit to escape from the fire.

Never set up the tent near the river, under the tree of other objective hazards.

This tent designed for use in mainly moderate weather conditions.

Keep exits clear.

Make sure ventilation openings are open all the time to avoid suffocation.

Set the ventilation openings to the right position and keep them locked up.

Overload may cause danger.

KEEP THE POLES INFLATABLE ENOUGH. UNDER-INFLATION MAY AFFECT TENT PERFORMANCE.

DO NOT OVER-INFLATE THE POLES. OVER-INFLATE MAY DAMAGE THE POLES.

DO NOT OPEN THE ZIPPER OF THE AIR POLES ESPECIALLY WHEN IT’S FULLY INFLATED.

Outer tent: 15ft.11in. x 8ft.10in. x 6ft.7in. / 485 x 270 x 200cm

Inner tent: 6.88ft x 8.20ft x 6.23ft. / 210 x 250 x 190cm

Pitching dimension: 22.47ft x 15.42ft. / 685 x 470cm

SAVE THESE INSTRUCTIONS 

SETTING UP THE TENT

1. Lay the tent on the ground. Pull the four corners outwards.

2. Secure the four corners by pushing the pegs into the ground loops.

3. Inflate the tent with hand pump. The ideal inflation pressure will be around 6PSI or when the poles feel fully 

inflated. 

4. Secure the tent with the pegs and guy ropes.

NOTE:

 Drawings for illustration purpose only. May not reflect actual product. Not to scale.

MAINTENANCE AND STORAGE

: 

1. Clean the tent and remove any stains with a sponge and cool water. 

Please use non-detergent soap for serious cleaning.  

2. Please allow all parts to dry thoroughly before you repack the tent. 

This will prevent the formation from mold, odours and discolouration.

3. Replace the pole in case of air leakage. 

4. Silicone spray could be uses to zippers if they stick.

5. Deflate the tent by unscrewing the screw valve.

6. Store the tent in the stuff sack and place it in a cool, dry area out of sunlight and away from heat sources 

and rodents.

P3046B
P5C507
P5548
F4C073B-02
P61533
P61536
P61535
P5617

P3046B
P5C507
P5548
F4C073B-02
P61534
P61536
P61535
P5617

High pressure pump
Pressure Gauge
Peg
Screw Valve
Tent
AIRFRAME

TM

 Pole (544cm, Red mark on the end)

AIRFRAME

TM

 Pole (516cm,Yellow mark on the end)

Big peg

QTY.

1
1

18

3
1
2
1
4

68078E

68077E

NAME

S-S-004383

Reviews: