background image

BEST

STAND®

S I T - T O - S T A N D   L I F T

M o d e l :   S A 4 0 0 H / S A 4 0 0 H E

Ensure the product has been assembled according to the instructions in this 

manual. All operators should read and understand the instructions for safe and 

proper operation of the patient lift.

SA400HE model shown

SA400H model shown

Summary of Contents for SA400H

Page 1: ...4 0 0 H S A 4 0 0 H E Ensure the product has been assembled according to the instructions in this manual All operators should read and understand the instructions for safe and proper operation of the...

Page 2: ...he manufacture date can be found on the serial number label that is located at the top of the mast The YY in the serial number is the manufacture year and the MM is the manufacture month This product...

Page 3: ...n adjustable cushioned knee pad for additional comfort and support while patients are being transferred The SA400H and SA400HE have a compact base for maneuvering easily while still providing a wide l...

Page 4: ...physical contact with the patient in order for the device to carry out its intended Do Not Iron Item may not be smooted or finished with an iron Class II symbol To identify equipment is designed that...

Page 5: ...ise severely handicapped The patient lift should be used solely for transferring a user patient from one utility beds chairs toilets etc to another The patient lift should not be used for transporting...

Page 6: ...DOES NOT consist of any materials or ingredients to which patients are exposed that may cause bodily harm or injury Prolonged exposure or physical contact with any part of the equipment WILL NOT caus...

Page 7: ...LC ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF BESTCARE LLC IS PROHIBITED 9 8 2017 1 of 1 DaTong Wrench ALL DIMENSIONS IN MM 1 6 6 30 30 120 120 400 0 1 0 2 0 3 0 5 Easy T...

Page 8: ...9 7 C 909 2 35 8 909 2 35 8 D 70 1 2 8 70 1 2 8 E 294 2 11 6 294 2 11 6 F 763 3 30 1 763 3 30 1 G 689 2 27 1 689 2 27 1 H 577 0 22 7 577 0 22 7 I 322 6 12 7 322 6 12 7 J 633 3 24 9 633 3 24 9 K 298 5...

Page 9: ...Molded Kneepad Optional Features 1 Charging Cradle 2 Second Battery pack Specifications of Control Unit Input Voltage 220 240VAC 50Hz 110 120VAC 60Hz Output Voltage 24 VDC Battery Pack 24 VDC 5AH Lift...

Page 10: ...SA400HE Actuator may vary based on the lift model TA1 Actuator SA Hydraulic Pump TC12 Control Box No Control Box SA400H 9...

Page 11: ...tion Step 1 Remove the base from box Step 2 Insert the mast and secure it using the bolt and threaded knob as follows Step 3 Insert the boom to the mast and secure it using the bolt and threaded knob...

Page 12: ...00H to the bracket on the mast and secure it using a pin and retaining ring as follows Step 5 Insert the upper end of the actuator SA400HE or the hydraulic pump SA400H to the bracket on the boom and s...

Page 13: ...eepad frame with the plastic U washer to the kneepad Choose one of the three holes on the tube depending on the desired kneepad height Then secure it using bolt nut and washers as follows Step 8 Pull...

Page 14: ...13 Control Box for SA400HE Only 4 2 5 M5 SCREWS M4 SCREWS UNLESS OTHERWISE SPECIFIED DATE DRAWN BY 2920 PACIFIC DRIVE NORCROSS GA 30071 ALL DIMENSIONS IN MM 1 6 0 1 1 3...

Page 15: ...be one that serves the needs of the patient while providing the patient with optimal safety Never interfere with the lift unless instructed by the attendant Have a doctor nurse or medical attendant ex...

Page 16: ...onal Battery Pack Optional Power Control Unit Overview 15 1 Connect Actuator as shown above 2 Connect Hand Control as shown above WARNING Contains a long charger cord that may cause strangulation if u...

Page 17: ...le Release Pressed in Turn the emergency stop button clock wise the LCD Display Panel will show one of the four signs below The sign will display for 5 seconds Then the lift will go into standby mode...

Page 18: ...17 LED Indicator Green In Use Blank Standby Lifting Lowering Operating Lift Using Hand Control Operating Lift Using LCD Display Panel...

Page 19: ...the LCD Display Panel will show the sign on the left either when the emergency stop button is released or when a button on the LCD Display Panel is pressed Lift operation is deactivated Battery needs...

Page 20: ...he boom Turn the release tab counter clockwise until it stops Use the handlebar to pump the piston To lower the boom Slowly turn the release tab clockwise stop once the boom is slowly lowering Turn th...

Page 21: ...odel Sling Size SL TP331 S SL TP332 M SL TP333 L SL TP334 XL Stand Assist Buttock Strap Stand Assist Sling Stand Assist Toileting Sling Available slings compatible with Stand Assist Lift 20 If the pat...

Page 22: ...to stabilize the sling during lifting 6 Have patient grasp the arms of the boom and tilt head back slightly 7 Make sure the patients feet are firmly on the platform and knees are touching the kneepads...

Page 23: ...being lifted 6 Fit the Stand Assist sling following Fitting Stand Assist Sling instructions the Buttock strap MUST be used with the Stand Assist sling These slings are designed to compliment one anoth...

Page 24: ...5 Have the patient s hands holding the handles For patients who cannot hold the handles have them hold their arms around the chest 6 Press the UP button on the hand control 7 Before the patient s bod...

Page 25: ...g straps through the other strap 7 Attach should straps loop to the hooks in upper ends of the boom A to a and B to b 8 Attach the proper leg strap loop to the hooks in the lower end of the boom C to...

Page 26: ...10 years or 20 000 cycles The expected lifetime of the electrical components are 3 years Contact Bestcare for recycling information First Received Monthly Every 3 Months Check connections between boo...

Page 27: ...propyl alcohol For slings with rigid supports remove the plastic inserts before washing Look for an opening near the plastic inserts for removal Machine wash warm or cold Do not wash with other colors...

Page 28: ...on usage The actuator will either go up or down but not both Replace your hand control as it is at the end of its life cycle Your control box may be malfunctioning There is a grinding sound inside th...

Page 29: ...cy Lowering Device is located at the top of the actuator shaft It is intended for use if the actuator or electronics fail to operate while the patient is suspended in midair The device consists of a p...

Page 30: ...e date for the specified time period WARRANTY PERIOD PRODUCT OR COMPONENT Three 3 Years Patient lift frame or spreader bar Two 2 Years Actuator control box pendant charger weigh scale Stand Aids all c...

Page 31: ...30 Notes...

Page 32: ...Bestcare LLC 2920 Pacific Drive Norcross GA 30071 Ver 2020 02 www bestcarellc com 2019 Bestcare LLC...

Reviews: