WATER CONNECTION 

Water supply for the humidifier should be taken from 
a nearby hot water line but cold water is acceptable.  
All  water  connections  should  be  made  at  ground 
floor  level.    Do  not  use  any  water  line  served  by  a 
water softener.  If your home has a water softener, 
make  the  water  connection  up  stream  of  the  water 
softener.  A water softener is not a de-mineralizer.  It 
merely exchanges various hard-ions for soft-ions in 
the water.  These soft-ions or minerals, will build up 
in  the  transfer  media  in  the  humidifier,  causing  the 
need for more frequent servicing.  The evaporation 
of softened water may also produce a white powder 
which  may  be  carried  in  to  the  duct  system  and 
ultimately in to the home.  The saddle tapping valve 
should be mounted on top of, or on the side of the 
water line.  If the valve is installed on the bottom of 
the  water  line  it  could  clog  with  sediment  from  the 
water  line.    Refer  to  the  instructions  on  the  saddle 
valve package and proceed as follows.  For copper 
water  lines  the  valve  is  self  piercing.    Mount  the 
saddle valve to the top or side of the water line, then 
turn  “T”  handle  to  the  clockwise  until  it  stops  to 
pierce and seat the valve to the pipe.  Open to flush 
the  valve  and  close  it  again.   Then  connect  plastic 
water  line  from  the  valve  to  the  humidifier  making 
sure not to kink it or run it near any hot flue pipes.  
Connect  water  line  to  valve  and  humidifier  with 
supplied hardware.  Now open the saddle valve turn-
ing the tee handle counter clockwise until fully open.  
Check  for  water  leaks  and  repair  as  necessary.    

Attic installations are not recommended 

INSTALL DOOR AND EVAPORATIVE PAD 

DRAIN CONNECTION 

Make sure the evaporative pad is positioned in the 
door correctly.  The black mark on the edge  of the 
pad indicates the top.  The pad slides into the door 
and rests against the four legs located inside. 
 
Position  the  bottom  edge  of  the  door  in  the  tray 
located on the lower opening in the housing.  Then 
simply  push  the  top  of  door  closed  until  is  has 
snapped into place.   To remove door just push down 
on the two tabs located at the top of the door and pull 
the door away from the housing. 

Connect  the  1/2”  plastic  tubing  to  the  drain  spout 
and secure it.  The spout is located at the bottom of 
the housing.  Keep the tubing as short as possible 
and  avoid  sharp  bends.    The  drain  line  should  be 
routed  on  a  continous  downward  slope  and  into  a 
suitable drain.  

WARNING: failure to connect the 

drain tubing could result in a flood. 

SETTING THE HUMIDISTAT 

Most people feel comfortable between 35% to 45% 
RH, but the proper relative humidity for your home 
depends  upon  many  factors  such  as  outside  air 
temperature,  type,  and  placement  of  insulation, 
vapor  barrier,  effectiveness  of  weather  stripping, 
type  of  windows  and  doors  (including  frames  and 
jams),  and  whether  storm  windows  and  doors  are 
used.  With all of these variables it is nearly impos-
sible to recommend a proper humidity setting.  The 
best humidstat setting is one that you are comfort-
able with.  Also, as the outdoor temperature fluctu-
ates,  it  may  be  necessary  to  adjust  the  humidity 
level a few times during the heating season.  Refer 
to the “Relative Humidity Chart” as a starting point 
for  your  proper  humidistat  setting.    Generally,  in  a 
tighter  and  better  insulated  house,  the  humidistat 
may  be  set  higher  than  in  a  drafty,  uninsulated           
house.  

Copyright 2007 ©                    , All Rights Reserved 

  281 Keyes Ave. Hampshire, IL 60140 • 847-683-7990 • Fax 847-683-7301 • www.bestairpro.com 

® 

® 

BESTAIR PRO MODEL GH2500 FLOW-THRU HUMIDIFIER

INSTALL HUMIDISTAT 

The BestAir PRO Humidistat should be installed as 
described  in  the  installation  instructions  supplied 
with the humidistat.

 

Summary of Contents for GH2500

Page 1: ...tubing Turn off power to the furnace before installing the humidifier Test fit the GH2500 housing on the side of the warm air plenum Before proceeding verify that adequate clearances are available for...

Page 2: ...ual ADDITIONAL RECOMMENDED PARTS 1 Relay with 120 volt current sensing coil for furnaces with multi speed blower motors 2 4x4 wire box to mount transformer and enclose line voltage connections 3 18awg...

Page 3: ...nsformer to the humidistat Then from the humidistat to the other wire on the solenoid valve Make sure not to route wires where they can be burned or chaffed See example wiring solutions to the right o...

Page 4: ...black mark on the edge of the pad indicates the top The pad slides into the door and rests against the four legs located inside Position the bottom edge of the door in the tray located on the lower o...

Page 5: ...Y CHART Suggested Humidistat Settings OUTDOOR TEMPERATURE ADJUST RH TO 30 F 20 F 10 F 0 F 9 F 40 35 30 25 20 Table 1 Suggested RH set points for different outdoor temperatures All power humidifiers re...

Page 6: ...bris RH level in the home is low or will not rise 1 Humidity control is set to low 2 Water supply has been turned off 3 Media pad is clogged with mineral buildup 4 Media panel is installed incorrectly...

Page 7: ...7 SERVICE NOTES Copyright 2007 All Rights Reserved 281 Keyes Ave Hampshire IL 60140 847 683 7990 Fax 847 683 7301 www bestairpro com...

Page 8: ...8 SERVICE NOTES Copyright 2007 All Rights Reserved 281 Keyes Ave Hampshire IL 60140 847 683 7990 Fax 847 683 7301 www bestairpro com...

Reviews: