- 11 -
FIG.14
FIG.15
FIG.16
DUCTED INSTALLATION ONLY
10. Press the discharge collar into the
duct connector of the range hood.
Fig. 14.
11. Run 6” diameter metal ductwork
to the outside location. Install an
appropriate wall or roof cap with
damper to exhaust air to the out-
side.
12. Tape all duct joints with aluminum
duct tape.
13. Plug power cord into wall outlet. Fig.
15.
14. Install upper and lower decorative
flues onto the range hood.
- Vents are concealed on 8-foot
ceilings. Fig. 16
- Vents are exposed on 9-foot ceil-
ings. Fig. 17.
15. Secure upper flue to flue mounting
bracket with (2) 3.9 x 6 mm screws.
DISCHARGE
COLLAR
6” ROUND
DUCT
POWER
CORD
FIG.17
VENTS
CONCEALED
8 FT. CEILING
VENTS
EXPOSED
9 FT. CEILING
NON-DUCTED INSTALLATION
WITH FLUE AND PLENUM ONLY
Note: Purchase Model ANKWM34 Non-
ducted Recirculation Kit.
10. Do not install discharge collar
supplied with the range hood.
11. Attach the 5”-to-6” adapter to
blower discharge and tape joint with
aluminum duct tape. Fig. 18.
FIG.18
5” TO 6”
ADAPTER