PIK MOUNTINg

S

ize

 

of

 

the

 

cut

-

out

NOTE: The 3 1/2’’ notch must be cut only if the WCPI  

             optional wall control will be installed.

HH0040A

1 1/2”

HD0093A

17 1/16''

16 3/8''

32 1/2'' or 44 1/2''

3 1/2''

2 1/4'' min.

NOTE: If optional L series liner is used, refer to installation   

             instructions for size and location of the cut-out.

Suggested Custom Hood Internal Framework

HL0065

- 3 -

RMP Series Backsplash

(Stainless Steel wall

covering with warming

shelves. Optional)

L3336S, L3342S, L4548S

L4554S or L4560S

Custom Hood Liner (optional)

Model 415

7” Round

adjustable elbow

(optional)

8” Round 

adjustable elbow

(optional)

Model 412 

transition

(3¼” x 10” to 7”)

Adapter and damper 3¼’’ x 10’’

(supplied with P5 and P8 blowers)

Adapter and damper 3¼’’ x 14’’

(supplied with P8 blower)

Model P5 

single-blower

(500 cfm)

PIK33 OR PIK45

INSERT

- PIK33 

AND

PIK45

INSERT SYSTEM

-

INTERIOR BLOWERS

Flow deviator 

(supplied with P5 and P8 blowers)

Model 647

(7” Round

wall cap)

Model 634 or 644

(roof cap)

Model 643

(8” Round

wall cap)

8” Round

standard

duct

Model 407

(7” Round x 24’’

section)

7” Round

metal flexible

duct (optional)

8” Round 

metal flexible duct

(optional)

Model 413 

transition

(3¼” x 10” to 8”)

Model 459 

transition

(3¼” x 14” to 8”)

Model P8

dual-blower (900 cfm)

NOTE: The  dual  blower  P8  must  be 

installed with 8’’ round duct. If it 

is impossible to connect the dual 

blower  P8  to  a  8’’  round  duct, 

use  a 7’’  round  duct.  In  that 

case,  the  blower  performance 

will be decreased by 25%.

Rough-in kit 

(supplied with P5 and P8 blowers)

ALP36, ALP42, 

ALP48, ALP54 or ALP60

Ambient light panel (optional)

WCPI

Wall control

(Optional)

Summary of Contents for PIK33

Page 1: ...es clean easily Ambient light panel ALP Series for L Series custom hood liners Halogen lighting 36 and 42 _ 2 x 50 watt 48 54 and 60 _ 3 x 50 watt GU10 Lamps included Backsplash RMP Series Widths 36 42 48 60 Stainless Steel construction protects back wall and wipes clean easily WCPI Remote control With Stainless Steel faceplate to fit any décor INSERT SPECIFICATIONS 120 vac 60 Hz Amps without blow...

Page 2: ...5 and P8 blowers Adapter and damper 3 x 14 supplied with P8 blower Model P5 single blower 500 cfm PIK33 OR PIK45 INSERT PIK33 AND PIK45 INSERT SYSTEM INTERIOR BLOWERS Flow deviator supplied with P5 and P8 blowers Model 647 7 Round wall cap Model 634 or 644 roof cap Model 643 8 Round wall cap 8 Round standard duct Model 407 7 Round x 24 section 7 Round metal flexible duct optional 8 Round metal fle...

Page 3: ...500 cfm exterior blower Model 441 10 Round wall cap Model 437 High capacity roof cap Model 441 10 Round wall cap Model 421 10 Round vert in line damper Recommended for use with exterior blowers Model 410 10 Rd duct 2 ft sections 10 Round metal flexible duct optional In line and exterior blower rough in kit included with ILB3 ILB6 ILB9 ILB11 EB6 EB9 EB12 and EB15 blowers ALP36 ALP42 ALP48 ALP54 or ...

Page 4: ...EB6 EB9 EB12 OR EB15 BLOWER Vertical Outlet 5 1 4 16 1 8 9 5 8 dia 7 8 dia 1 11 16 6 11 16 HK0029 MODEL PIK45 WITH P8 BLOWER Vertical Outlet MODEL PIK45 WITH P5 BLOWER Vertical Outlet MODEL PIK45 WITH EB6 EB9 EB12 OR EB15 BLOWER Vertical Outlet 3 1 4 22 1 8 13 5 8 7 8 3 4 15 1 8 14 7 8 dia 8 round transition HK0034A 3 1 4 22 1 8 13 5 8 7 8 3 4 17 1 8 10 7 8 dia 7 or 8 round transition HK0033A 5 1 ...

Reviews: